Site Preparation
Electrical Requirements
The electrical supply should be located within the shaded
area shown in the illustration below. Follow the National
Electrical Code and local codes and ordinances when
installing the receptacle. A separate circuit, servicing only
this appliance is required.
IMPORTANT NOTE: The electrical outlet must be placed
so the grounding prong is to the right of the thinner
blades. The outlet must be flush with the back wall.
Model UC-24RO is designed and safe for use in outdoor
applications. When installed outdoors, a ground fault
circuit interrupter (GFCI) is required to reduce the risk of
electrical shock. A GFCI is not recommended for use with
other undercounter models and may cause interruption of
operation.
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance.
Electrical Requirements
Power Supply
Circuit Breaker
Receptacle
LEFT SIDE
OF OPENING
2"
(51)
1
15
/
"
2
(394)
3"
(76)
FRONT VIEW
Location of electrical supply.
115 V AC, 60 Hz
15 amp
3-prong grounding-type
Plumbing Requirements
MODEL UC-24CI
For model UC-24CI, the water supply line for the ice
maker should be located within the shaded area shown in
the illustration below. Connect the water line from the ice
maker water valve to the house water supply. Use an
easily accessible shut-off valve between the water supply
and the unit. Do not use self-piercing valves. A saddle
valve kit is available from your authorized Sub-Zero
dealer.
A line filter is required when water conditions have a high
sediment content. The ice maker operates on water
pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar).
A reverse osmosis system can be used, provided there is
a consistent water pressure of 20 psi (1.4 bar) to 100 psi
(6.9 bar) supplied to the water valve at all times.
IMPORTANT NOTE: In some cases a reverse osmosis
water filter system may not be able to maintain the
minimum water pressure consistently.
Plumbing Requirements
Water Supply Line
Water Pressure
Excess Water Line for Connection
SHADED AREA
EXTENDS 1
/
"
2
(13)
FROM BACK WALL
2"
(51)
1
15
/
"
2
(394)
3"
(76)
FRONT VIEW
Location of water supply.
6
1
/
" OD copper line
4
20–100 psi
(1.4–6.9 bar)
26"
min
(660)