Download Print this page

Valcom VIP-848A Quick Start Manual page 2

Advertisement

INSTALLATION
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses and can radiate radio
frequency energy and if not installed and used
in accordance with the instruction manual,
may cause harmful interference to radio
communications. Operation of this equipment
in a residential area may cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
Precautionary Designations
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
Mounting
The VIP-848A is designed for wall or table
mounting.
Table: Provided with the VIP-848A are four
rubber stick on pads. Peel these pads off their
carrier backing and place at the four corners of
the bottom of the unit.
Wall: Using the bracket and hardware provided,
secure the VIP-848A to the wall.
Power Connections
The preferred method of powering a VIP-848A is
via a Power over Ethernet (PoE) switch meeting
the 802.3af specification.
If the rear panel barrel connector is used for
power, the preferred power supply is a Valcom
VIP-324D.
Make all required signal connections before
applying power to the unit. If powering via 802.3af,
make sure all signal connections via the rear
panel are made then connect the VIP-848A to the
Ethernet switch.
If power is provided via the barrel connector,
make sure all signal connections are secure.
Attach the unit to the network via the front panel
RJ-45 Ethernet connector. Apply power by
plugging the power supply in to the VIP-848A via
the barrel connector on the rear of the VIP-848A.
Network Connection
The VIP-848A has one RJ-45 network connector
on the front panel.
Use a standard Ethernet patch cable to connect
the VIP-848A to an Ethernet switch. If the
Ethernet switch is 802.3af compliant the VIP-848A
will draw power from it.
Signal Connections
The VIP-848A has 16 signal connectors on the
rear panel:
8 Contact Closure Inputs
8 Relay Contacts that are programmable as
Form A or Form B
2
947645

Advertisement

loading