SENSIT Technologies 906-00000-08 Instruction Manual

Combustible gas detector

Advertisement

Quick Links

WARRANTY
®
Your SENSIT
HXG-2d instrument is warranted to be free from
defects in materials and workmanship for a period of two years
after purchase (excluding sensor, calibration and batteries). If
within the warranty period your instrument should become inop-
erative from such defects, the unit will be repaired or replaced at
our option. This warranty covers normal use and does not cover
damage which occurs in shipment or failure which results from
alteration, tampering, accident, misuse, abuse, neglect, or im-
proper maintenance. A purchase receipt or other proof of date of
original purchase will be required before warranty performance
will be rendered. Instruments out of warranty will be repaired for
a service charge. Return the unit postpaid and insured to:
SENSIT TECHNOLOGIES
851 Transport Drive
Valparaiso, IN 46383
Phone: (219) 465-2700
Fax: (219) 465-2701
This warranty gives you specific legal rights and you may also
have other rights which vary from state to state.
MADE IN USA
#750-00022 Instruction Manual
10-30-09 Revised 3-27-14 V5
SENSIT® HXG-2d
Combustible Gas Detector
INSTRUCTION MANUAL
Read and understand Instructions before use.
710183
UL 913
Intrinsically Safe for Use in
Class I, Groups C and D, T3
Hazardous Locations
AEx ia IIB T3
IP20
For use in clean dry areas only.
Suitable for combustible gases
such as Methane, Butane, Propane
and Natural Gas

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 906-00000-08 and is the answer not in the manual?

Questions and answers

Summary of Contents for SENSIT Technologies 906-00000-08

  • Page 1 Instruments out of warranty will be repaired for Class I, Groups C and D, T3 a service charge. Return the unit postpaid and insured to: Hazardous Locations SENSIT TECHNOLOGIES AEx ia IIB T3 IP20 851 Transport Drive For use in clean dry areas only.
  • Page 2 WARNING: All Accessories are to be used in an area known to be Optional Accessories and Parts non-flammable. Extension Adapter 870-00012 WARNING: Use only sensor from SENSIT Technologies. PN 375-2611-01 Calibration Kit 2.5% Methane 881-00017 Calibration Kit .5% Methane 881-00075...
  • Page 3 GENERAL DESCRIPTION SPECIFICATIONS SENSOR SPECIFICATIONS The Sensit® HXG-2d is designed to detect combustible gases. TYPE RESOLUTION RANGE ACCURACY This instrument incorporates an advanced low power semicon- 10ppm 0-990ppm ±10% ductor sensor to measure a wide variety of combustible gases 0.1% 0-100%LEL ±10% in both the PPM and %LEL range.
  • Page 4 PRODUCT FEATURES PRODUCT FEATURES continued from page 5 continued from page 6 Sensit® HXG-2d instruments are constructed of durable high There are 3 operational button pads on the front of all impact ABS to withstand the rigors of field use. Sensit®...
  • Page 5 BATTERY INSTALLATION/REPLACEMENT OPERATION AND USE WARNING: Always change batteries in an environment CAUTION: Always start any Sensit® HXG-2d in a gas free free of combustible gases. environment to ensure a proper zero. 1. Push and hold the power button (A) until the display and backlight WARNING: Do not mix batteries of different type or age.
  • Page 6 OPERATION AND USE OPERATION AND USE continued from page 8 continued from page 10 4. All instruments read with a resolution of 10ppm up to 990ppm. NOTE: These instruments have cross sensitivities to a variety of gases. The scale automatically switch to LEL when 990ppm is exceeded with a resolution of 0.1% LEL.
  • Page 7 SENSIT TECHNOLOGIES may cause inaccurate read- ings. Repairs may be required if the instrument fails to calibrate. Use only sensors supplied by SENSIT TECHNOLOGIES or their authorized representative. NOTE: During the calibration process the numbers on the dis- play are not the actual gas concentration.
  • Page 8 2-60% WARNING: Substitution of components may impair intrinsic safety. Show PPM 10PPM Resolution WARNING: Use only sensor from SENSIT Technologies. The Above settings are field adjustable: Part Number 375-2611-01 Setting Display Mode For %LEL & Alarm Setpoint For %LEL While the unit is on and in the working display, push the A and C buttons until the display shows OPt.

This manual is also suitable for:

Hxg-2drHxg-2d906-00000-09

Table of Contents