13-2. Outdoor unit low noise operation function (option)
Change the outdoor unit low noise operation by using this setting.
CAUTION
• When the low noise operation function is working, cooling and heating capacity will de-
crease.
• When changing the settings, explain to the customer beforehand that the capacity decreas-
es.
NOTES:
• When SET1-4 is OFF, optional Central remote controller is required to use this function.
• When SET1-4 is ON, "Operation" and "Non-operation" mode of this function cannot be
switched from the Central remote controller.
SET1-4
ON
OFF
SET2-1
ON
OFF
13-3. Changing the current limit function
Change the outdoor unit current limit function by using this setting.
CAUTION
• When the current limited function is working, cooling and heating capacity will decrease.
• When changing the settings, explain to the customer beforehand that the capacity decreases.
SET2-3
OFF
ON
OFF
13-2. Outdoor unit low noise operation function (option)
Setting
Continuous operation
Follow the Central remote controller
settings
Setting
Lower
SET2-4
OFF
OFF
ON
- 438 -
Low
Current
Factory setting
Full
16.0 A
12.0 A
Factory setting
Factory setting