Safety Devices - Fujitsu ARXG22KMLB Design & Technical Manual

Hide thumbs Also See for ARXG22KMLB:
Table of Contents

Advertisement

12. Safety devices

Type of
protection
Current fuse
Circuit protection
(Main PCB)
Fan motor
Thermal protector
protection
Temperature thermistor
(Discharge temp.)
Compressor
Temperature thermistor
protection
(Compressor bottom temp.)
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY mode)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
Activate
Reset
- 434 -
Model
AOYG36KBTA5
250 V, 5 A
250 V, 20 A
250 V, 3.15 A
125 ±10 °C
Fan motor stop
120 ±10 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
108 °C
Compressor stop
After 3 minutes, and 80 °C or less
Compressor restart
-20 °C
Compressor stop
-15 °C
Compressor restart
12. Safety devices

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents