Distributed CC-1 Zone Controller Connection to the Amplifier

For installations using multiple CC-1 zone controllers, you can also connect the zone controllers to the CV41 4-to-1
Converter, then create a single home run from the CV41 back to the amplifier. Create these connections using CAT 5 cables
and RJ-45 connectors.
The CV41 connects two CC-1 zone controllers to a PS602, or up to four CC-1 zone controllers to a PS604. Each zone
controller can be independently configured to control any output, or combination of outputs.
If only one CC-1 is used to control all outputs, then the CV41 is not required, as the PS602 and PS604 can accept one RJ-45
connection.
Figure 11. Distributed CC-1 ControlCenter zone controller connection to amplifier
PowerShare
Adaptable Power Amplifier
Installation Guide
CAT 5 cable
7.6 m (25 ft) max
SIGNAL
1
2
3
4
POWER
LIMIT
Remote Volume Control
CAT 5 cable
609 m (2000 ft) max
PS604
English 27