Download Print this page
Moxa Technologies NPort W2250A-EU Quick Installation Manual

Moxa Technologies NPort W2250A-EU Quick Installation Manual

Hide thumbs Also See for NPort W2250A-EU:

Advertisement

Quick Links

NPort W2150A/W2250A Series
Quick Installation Guide
Moxa Americas:
Toll-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa Europe:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa India:
Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
Version 6.3, April 2019
Technical Support Contact Information
www.moxa.com/support
 2019 Moxa Inc. All rights reserved.
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Asia-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
P/N: 1802021503016
*1802021503016*

Advertisement

loading

Summary of Contents for Moxa Technologies NPort W2250A-EU

  • Page 1 NPort W2150A/W2250A Series Quick Installation Guide Version 6.3, April 2019 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0 Tel: +886-2-8919-1230 Fax:...
  • Page 2: Package Checklist

    Overview The NPort W2150A/W2250A wireless device servers are an ideal choice for connecting serial devices or Ethernet devices, including PLCs, meters, and sensors, to an IP-based wireless LAN or Ethernet LAN. Features • Link any serial device to an IEEE 802.11a/b/g/n network •...
  • Page 3: Hardware Introduction

    Hardware Introduction The NPort W2150A models have one serial port; the NPort W2250A models have two serial ports. Both models support RS-232/422/485 operation with DB9 connectors and include one 10/100M Ethernet port. NPort W2150A/W2150A-T NPort W2250A/W2250A-T Reset Button: The reset button is used to load the factory default settings.
  • Page 4 Name Color Function Steady on: Wireless enabled Blinking: The NPort can’t establish a WLAN Green WLAN connection with AP (Infrastructure) or station (Ad-Hoc) Wireless not enabled Orange The serial port is receiving data Serial 1 Green The serial port is transmitting data Serial 2 No data is flowing to or from the serial port 1 Red -...
  • Page 5: Software Installation Information

    NOTE Do not use the 1 kΩ setting while in RS-232 mode. Doing so will degrade the RS-232 signals and reduce the effective communication distance. First-Time Hardware Installation STEP 1: After removing the NPort W2150A/W2250A from the box, use a crossover Ethernet cable to connect the NPort’s RJ45 Ethernet port directly to your computer’s Ethernet port.
  • Page 6: Pin Assignments And Cable Wiring

    Wizard in the left navigation panel. The wizard will prompt you to configure the IP address, SSID, and security mode. For other settings, use the factory defaults or modify the settings for your application. For software installation, download the relative utilities from Moxa's website: https://www.moxa.com/support/support_home.aspx?isSearchShow=1 •...
  • Page 7 EN 55032 Class A/EN 55035 ETSI EN 301 489-17, ETSI EN 301 489-1 FCC: FCC Part 17 Subpart B, Class A FCC Part 15 Subpart B, Class A Safety UL 60950-1 LVD: EN 60950-1 DSPR: ARIB-STD 33, ARIB-STD 66 - 7 -...