Cedar Ridge CRHQD250T Owner's Operation And Installation Manual page 13

Vent-free gas stove
Table of Contents

Advertisement

Available languages

Available languages

For propane/LP installations, apply pipe
joint sealant lightly to male threads. This will
prevent excess sealant from going into pipe.
Excess sealant in pipe could result in clogged
heater valves.
The installer must supply an external regula-
tor. The external regulator will reduce incom-
ing gas pressure. You must reduce incoming
gas pressure to between 11" and 14" of w.c.
If you do not reduce incoming gas pressure,
heater regulator damage could occur. Install
external regulator with the vent pointing down
as shown in Figure 11. Pointing the vent down
protects it from freezing rain or sleet.
Install sediment trap in supply line as shown
in Figure 10. Place sediment trap where it is
within reach for cleaning. Place sediment trap
where trapped matter is not likely to freeze.
A sediment trap traps moisture and contami-
nants. This keeps them from going into heater
controls. If sediment trap is not installed or is
installed wrong, heater may not run properly.
Ground
Joint Union
Tee Joint
Reducer
Bushing to
Test Gauge
1/8" NPT
Connection*
1/8" NPT
Plug Tap
Tee Joint
Sediment
Pipe Nipple
Trap
Gap
Figure 10 - Gas Connection
* Purchase the optional CSA design-certified equipment
shutoff valve from your dealer.
200029-01A
INSTALLATION
WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct
all leaks at once (see page 14).
Figure 9 - Gas Regulator Location and
Gas Line Access Into Stove Cabinet
3/8" NPT
Pipe Nipple
Equipment
Shutoff Valve
Natural Gas
From Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)
Propane/LP
From External
Regulator
(11" W.C.**
to 14" W.C.
3" Minimum
Pressure)
www.usaprocom.com
Gas Inlet Regulator
Connection
External
Regulator with
Propane/LP
Vent Pointing
Supply Tank
Down
Figure 11 - External Regulator
with Vent Pointing Down
13

Advertisement

Chapters

Table of Contents
loading

Table of Contents