Viking CVBI7360 Installation Manual page 10

Integrated refrigerator / freezer
Hide thumbs Also See for CVBI7360:
Table of Contents

Advertisement

General Information
Viking Range, LLC is not responsible
for property damage due to improper
installation or water connection.
• Connect 1/4" (6 mm) fl exible copper tubing to
household plumbing in compliance with local
codes and ordinances.
• Length of copper tubing must reach from water
supply connection to the unit connection with an
additional length to facilitate moving the unit out
of enclosure for cleaning or service. Tubing should
be soft instead of rigid and ends should be free of
burrs.
• Copper tubing route must be above 35º F
(1.7º C) to prevent water line from freezing.
• DO NOT use plastic water lines from
the household plumbing to the water
inlet valve connection on the refrigeration
unit.
DO NOT use the self-piercing feature of
a saddle valve.
The hole made by the
piercing lance is too small for the water
fl ow rate required by the ice maker.
• If saddle valve is not used, place a separate shut-
off valve in an easily accessible location between
DO NOT
water supply and the unit.
valve behind the unit.
• The installation of Viking Range, LLC units with
a reverse osmosis system is acceptable
as the water pressure remains within the
allowable PSI as stated below.
to note that with many reverse osmosis systems,
the pressure starts off high, but then it decreases as
the water level of the reverse osmosis storage area
drops. This must be considered when checking the
water pressure coming into the unit.
• Connect a vertical or horizontal 1/2" (1.3 cm) to
1-1/4" (3.2 cm) COLD water line near water area.
• Run water line through the fl oor, back, or side wall
in area shown on page 7. Connect to water supply
coming from back of unit on the left side.
• Water pressure must be greater than 20 psi and
less than 120 psi on non-dispenser units and
greater than 35 psi and less than 120 psi on
dispenser units.
Area Requirements
• Most of the unit's weight is at the top.
Extra care is needed when moving the unit to
prevent tipping.
DO NOT
operating position.
• All four leveling legs must contact the fl oor to
support and stabilize the full weight.
DO NOT
• Remove exterior shipping materials prior to
moving unit into home, except door latching
device.
• Use two or more people to move and install unit.
Failure to follow this instruction can result in back
or other injury.
• To avoid personal injury, wear gloves when
performing any installation procedure and
wear eye protection when cutting metal
straps.
Tip Over Hazard
Appliance is top heavy and tips easily when not
completely installed. Keep doors closed until
appliance is completely installed and secured per
install shut-off
installation instructions. Use two or more people to
move and install appliance. Failure to do so can result
in death or serious injury.
as long
Unpacking Unit
It is important
1.
Remove top and bottom strap.
2.
Remove top cap.
3.
Cut carton rear approximately 1/4" (0.6 cm) to
1" (2.5 cm) from right corner with a utility knife
extended 1/4" (0.6 cm).
4.
Remove carton and exterior packaging. Save
cardboard shipping material to protect fl oor
surface when installing unit. Remove anti-tip
board, kickplate and side trim from rear of unit.
10
10
remove protective fi lm until unit is in
drop unit.

Advertisement

Table of Contents
loading

Table of Contents