Burnham K2WTC Installation, Operating And Service Instructions page 114

Condensing high efficiency direct vent gas-fired hot water combi boiler
Table of Contents

Advertisement

Sage Zone Panel Expected Heat Rate Adjustment Screens (HeatMatch Software)
The Control is shipped with defaults that will provide improved operation. Adjustment is only required to optimize setup.
The expected heat rate adjustment is used to better match boiler output to the home heating needs. After receiving a "call for
heat" the Control first uses the expected heat rate value to set a maximum heat rate. The maximum heat rate is the highest heat
rate that the boiler can fire to at that moment. The maximum heat rate is the summation of the expected heat rates for the active
(turned on) zones. After establishing the maximum heat rate the Control then measures water temperature and fires the boiler only
as hard as required for the heat demand.
Example "call for heat"
durations for a four zone
house.
Maximum heat rate
limits firing rate and
prevents the Control
from firing to 100% in
response to a smaller
zone demands.
Figure 13.11: Four Zone House (with Sage Zone Control Connected)
Maximum modulation numbers are
shown in both RPM and kbtu/hr to
allow for easier understanding of boiler
heat rate.
Figure 13.12: Expected Heat Rate Adjustment (with Sage Zone Control Connected)
114
XIII. Operation
F. Changing Adjustable Parameters (continued)
Maximum Heat Rate:
Automatically adjusted
by the Control based on
the size and number of
zones calling for heat.
Actual Heat Rate:
Boiler is free to
modulate based on
temperature from
minimum to maximum
heat rate.
Note
This feature requires Zone Control
to be connected. Refer to Electrical
section for Zone Control connection
information.
The sum of Zone Expected Heat Rates
is used to calculate the active maximum
modulation rate
107774-01 - 9/17