G PS·Data Mode Connection
To apply the PS·Data mode, connect the system controllers
as follows.
1. Connect the system controllers to the DATA 1 port of
Video Output Board 1.
Notes:
• In the factory default, the DATA 1 port is set for the ter-
minal mode connection. To apply the PS·Data mode
connection, perform the DATA port settings in DATA
PORT of SETUP MENU (refer to p. 53) or "System" –
"DATA Port" of WJ-SX650 Series Administrator Console.
• Both of terminal mode and PS·Data system controllers
cannot be connected to the same DATA port.
• DATA 1 port of Video Output Board 2 cannot be set for
the PS·Data connection.
• 1 200 m {3 937 ft} is the total length limit of cables
(between this unit and the system controller at the chain
end).
• Up to 4 system controllers can be connected in the
daisy chain. For system controllers in the daisy chain
connection, operator registration is not available. (The
same operator setting is applied for all the system con-
trollers in the PS·Data daisy chain.)
2. If using only one system controller, set the MODE
Switch #2 of DATA port connected to the system con-
troller to ON. If using two or more system controllers in
daisy chain connections, set the MODE Switch #2 of
DATA port of the chain-end unit to ON.
36
DATA 4
DATA 3
Video Output Board 2
HDR4/TMNL8
HDR3/TMNL7
Video Output Board 1
HDR2/TMNL4
HDR1/TMNL3
16
15
14
SYSTEM CONTROLLER
SYSTEM CONTROLLER
CONTROLLER NO.: 4
CONTROLLER NO.: 3
Line termination: ON
Line termination: OFF
Daisy chain connection
Unit Address: 1
Line termination OFF
OPERATE
OPERATE LED WILL BLINK
IF COOLING FAN MALFUNCTIONS
650
650
Matrix Switcher WJ-SX
ON
4
3
2
1
DATA 2
DATA 1
TERM.ON
TERM.OFF
ON
TMNL6
TMNL5
TMNL2
TMNL1/PS DATA
MODE
MODE
MODE
DATA
MODE
MODE
DATA
MODE
13
12
11
10
9
8
7
6
5
4
MONITOR OUT
VS IN
ALARM OUT 2
ALARM OUT 1
VS OUT
(THRU)
VS OUT
SERIAL
DATA2
DATA1
SYSTEM CONTROLLER
SYSTEM CONTROLLER
CONTROLLER NO.: 2
CONTROLLER NO.: 1
Line termination: OFF
Line termination: OFF
3. Set the system controllers to the PS·Data mode. (Refer
to the operating instructions of system controllers.)
4. Set the line termination of system controllers with the
MODE switches. (Refer to the operating instructions of
system controllers.) In the daisy chain connection, set
the line termination of chain end system controller to
ON. (Switch #5: ON)
5. In the daisy chain connection, set the CONTROLLER
NO. switches of system controllers to 1 to 4. The switch
setting must be different from each other. (Refer to the
operating instructions of system controller for details on
the CONTROLLER NO. switch setting.)
Note: When using system controllers in the PS·Data
mode, camera numbers that can be selected differ
depending on system controller models.
Example:
WV-CU950/650:
WV-CU360C/CJ:
Select the system controller models that are applic-
able for your system composition. When using 200
or more cameras in the PS·Data mode, apply WV-
CU950/650.
Unit Address: 2
Line termination ON
Line termination OFF
OPERATE
OPERATE
OPERATE LED WILL BLINK
OPERATE LED WILL BLINK
IF COOLING FAN MALFUNCTIONS
IF COOLING FAN MALFUNCTIONS
650
650
Matrix Switcher WJ-SX
Cable Kit
WV-CA48/10K
A
B
SYSTEM CONTROLLER
CONTROLLER NO.: 1
Line termination:
ON (#2: ON)
1 2
OFF
ON
OUT
EXTENSION 1
IN
TERM.
OUT X-3
3
2
1
Video output
OUT X-2
rear boards
Video Output Board 1 Only
OUT X-1
A
B
SYSTEM CONTROLLER
CONTROLLER NO.: 1
Line termination: ON
1 to 999
1 to 199
Unit Address: 3
650
650
Matrix Switcher WJ-SX