I Recorder Settings

Be sure to perform the settings for connected recorders in
SETUP MENU of recorders.
You can set w to t after connections. However, you must
set q separately for each recorder before connections. The
settings are performed in SETUP MENU (Advanced) of
each recorder.
q Unit Address (System)
Set the Unit Address (System) for each recorder in
"Comm" – "PS.Data Setup"
(Up to 16 recorders can be connected.) The unit
address setting must be different from each other.
w Unit Address (Controller)
Set the Unit Address (Controller) for each recorder in
"Comm" – "PS.Data Setup"
(Up to 4 recorders can be connected to a DATA port.)
The unit address setting must be different from each
other among recorders connected to the same DATA
port. When using WJ-RT416 Series, set the number
from 002 to 005 for Unit Address (Controller) of
[Communication Setup] - [PS.Data Setup].
e Camera Number Setup
Perform the Camera Number setting for each recorder
in "Comm" – "PS.Data Setup"
tings must be identical as the LCN settings of this unit.
Example: To supply video input signal from Camera 999 to
the CAMERA IN 16 connector of Recorder 16 (Unit
Address (System): 16), select CAM NO. 999 for CAM
PORT 16.
r Camera Control
Select PSD for CAM1 to CAM16 in "Comm" – "Camera
*2
Control"
.
t Event REC
To activate alarm recording, perform the event record-
ing settings surely. Refer to the operating instructions of
recorders for details. When using WJ-HD300 Series,
WJ-HD300A Series, or WJ-HD350 Series, maintain the
factory default for the following settings.
• PSD User setting in "System" – "Basic Setup": ADMIN
• Operation Mode setting of each Event Program – VMD,
VIDEO
LOSS,
and
"Schedule" – "Event Program": ALARM
(When setting QUICK for REC Type, Operation Mode
setting of Event REC in "SETUP MENU (Quick)" – "REC
& Event": ALARM)
• Settings in "Comm" – "PS.Data Setup" of SETUP MENU,
except for q to e. When using WJ-RT416 Series,
select "AL-M" for the alarm duration of "Term" or "VMD"
of [Event Setup] – [Alarm Rec. Setup].
*1 WJ-RT416 Series: [Communication Setup] - [PS.Data
Setup]
*2 WJ-RT416 Series: [Camera Control Setup]
*1
. 001 to 016 are available.
*1
. 001 to 004 are available.
*1
. The camera number set-
Terminal/Command
Alarm

I System Controller Connection

The following is a connection example to use system con-
trollers.
There are two options to connect system controllers to this
unit.
• Terminal mode: Normally, this operation mode is
applied. (When connecting System Controller WV-
CU360C/CJ, use Ver. 8.10 or later.)
• PS·Data mode: When other system units are connected
to this unit, and they are controlled by the same system
controller, this operation mode is applied. This mode
has operation restrictions. Refer to p. 86 OPERATION
(OTHER THAN TERMINAL MODE).
G Terminal Mode Connection
To apply the terminal mode, connect the system controllers
as follows.
1. Connect the system controllers to the DATA 1 to 4 ports
of the unit.
Notes:
• In the factory default, the DATA 3 and 4 ports are
set to HDR1 to 4 for recorder connection. To con-
nect system controllers, perform the DATA port set-
tings in DATA PORT of SETUP MENU (refer to p.
53) or "System" – "DATA Port" of WJ-SX650 Series
Administrator Console.
• Both of recorders and system controllers cannot be
connected to the same DATA port.
• 1 200 m {3 937 ft} is the total length limit of cables
(between this unit and the system controller at the
chain end).
• By connecting up to 4 system controllers to one
DATA port in the daisy chain, up to 16 system con-
trollers are available in the system. (Up to 16 sys-
tem controllers can log into the system at a time.)
• Daisy chain connection is available with System
Controller WV-CU950/650 (Ver. 2.00 or later).
2. Set the system controllers to the terminal mode. (Refer
to the operating instructions of system controllers.)
3. Set the CONTROLLER NO. switches of system con-
trollers to 1. (In the daisy chain connection, set 1 to 4
in
for each controller. The switch setting must be different
from each other. However, when connecting system
controllers to different DATA ports, you can use over-
lapped controller numbers.)
Note: Refer to the operating instructions of system con-
troller for details on the CONTROLLER NO. switch
setting.