Cleaning the drain pump
Note: Please read the information in
the Safety → Page 4 and Preventing
material damage → Page 10 sections
to ensure that you use the appliance
safely.
Requirement: The drain pump is
empty. → Page 45
Since water may remain in the
1.
drain pump, remove the pump cap
carefully.
Clean the interior, the thread on
2.
the pump cap and the pump hous-
ing.
Make sure that the impeller in the
3.
drain pump can be rotated.
Cleaning and servicing en
Insert the pump cap and screw it
4.
on as far as it will go.
90°
The handle on the pump cap must
be in a vertical position.
Insert the maintenance flap and
5.
lock it into place.
1
Close the maintenance flap.
6.
16.6 Cleaning the water outlet
hose at the siphon
Switch off the appliance.
1.
Disconnect the appliance's mains
2.
plug from the power supply.