EXPERT 2V2SA
10.6.

0-10V Heat Mat

When it is used to control heat mats, the
0-10V output runs at its maximum intensity
when the temperature of a chosen group of
probes gets lower than the heat mat set point.
Heat Mats
Heat mat
Status
0.5°F
On
Off
Heat Mat
Set point
Settings
1. From the main menu, select the option:
0-10V OUTPUT /CURVE
Make sure the function of the se-
lected 0-10V output is set to "Heat
mat" in the User Setup Menu before
adjusting the parameters below.
2. Use the navigation keys to select these
parameters:
Heat mat setp
80.5°F
Stop at day
Off
Probes
1234
Probe average T°
73.0°F
3. Set the following parameters:
(The parameter adjustment process is explained
in section 3.2 on page 8).
Heat Mat Set Point T° — Set the tempera-
ture below which the 0-10V heat mat turns
on. This heating set point ranges from -40
to 120°F (-40 to 48.9°C).
Heat Mat
Stop at day — Set the animal age over
which the 0-10V heating output must stop
being used. See "Setting the Day Number"
on page 10 to view/modify the current
day number.
Probes — The 0-10V heating output oper-
ates according to the average temperature
a chosen set of probes. Select what tem-
perature probes are used for this purpose.
Note that the blinking digits represent the
probes that are being used by the output.
Probe average T° — This is the average
temperature reading of the temperature
probes that were chosen above.
If the 0-10V heat curve is used, the
temperature at which the 0-10V
heating output starts must be de-
fined separately for each step of the
curve. See "0-10V Heating Curve" on
page 38 for further information about
this curve.