Heaters; Regular Heating Stages; Zoned Heating; Heating Timers - Airstream EXPERT 2V2SA User Manual

Table of Contents

Advertisement

EXPERT 2V2SA
10.

HEATERS

10.1.

Regular Heating Stages

Stages and can be used to control heating
units. If only one heating stage is enabled,
stage # will then be assigned for this purpose
(refer to the stage combination table in the
User Setup Menu).
A heating stage starts running when the
average room temperature gets lower than
the stage's start temperature; likewise, the
heating stage stops when the room tem-
perature gets higher than the stage's stop
temperature.
Heating Stages
Heating
level
Heat.
Stage 2
Heat.
Stage 1
Off
34
EXPERT 2V2SA, rev.10
10.2.
With the zoned heating functions, each heat-
ing stage can operate according to the aver-
age temperature of a chosen set of sensors.
When enabling this feature in the User Setup
menu, the controller automatically assigns
sensors 1 and 2 to the first heating stage
and sensors 3 and 4 to the second.
10.3.
The heating stages can run in timer mode
and according to two different timers based
on the room temperature. The graph below
shows how the heating timers work.
Timer
Status
Timer 2
Timer 1
Off
Room

Zoned Heating

To enable zoned heating, activate
the "Use zoned heaters" option in
the User Setup Menu.

Heating Timers

Heating Timers