Procedure once the power distribution grid becomes available again
If the power distribution grid becomes available again during secure power operation, the inverter
remains in secure power operation. The inverter only starts to feed in to the power distribution grid
again once the load has been disconnected and the miniature circuit-breaker is switched back on.
1. Disconnect the load.
2. Remove the plug for the load from the secure power socket-outlet.
3. Switch off the secure power socket-outlet so that the inverter begins feeding into the power
distribution grid again.
4. Switch the inverter miniature circuit-breaker back on.

6 The Message "Electr. arc detected" is displayed

✖ An electric arc occurred in the PV system.
✖ The red LED is permanently lit.
✖ The AFCI has tripped and the inverter is in permanent shutdown.
Danger of fire from electric arc
• Only test the AFCI for false tripping in the order described below.
• Do not deactivate the AFCI permanently.
1. If the following message appears on the display, tap on the enclosure lid: Electr. arc detected.
Please confirm by tapping.