ABB HT571908 Operation Manual page 70

Table of Contents

Advertisement

© Copyright 2016 ABB. All rights reserved.
Maintenance
Cleaning components mechanically
Cleaning the absorption segments
Loosen the tension bands (81270).
τ
Remove the cover grid (81266).
τ
Pull out the sheet-metal coverings (81137), bend them up and remove
τ
the absorption segments (81136).
Clean the absorption segments (81136).
τ
During cleaning, ensure that the absorption segments (81136) are only
cleaned with a mild jet of compressed air, soft brush or a damp cloth.
Have absorption segments which are heavily contaminated replaced
τ
by an official ABB Turbocharging Service Station.
Fitting the filter silencer
Insert the absorption segments (81136) into the sheet-metal coverings
τ
(81137).
Bend the sheet-metal coverings (81137) back into their original shape
τ
and insert them into the slot guides in the silencer body (81135).
Fit the cover grid (81266).
τ
Fit the tension bands (81270) and apply tension at the locks (81271).
τ
Damaged tension bands must be replaced with new ones.
τ
If provided, fit the filter ring (81265).
τ
Operation Manual / TPS44-F.. - TPS61-F..
5
5.4
Page 68

Advertisement

Table of Contents
loading