4.2.4
If provided
© Copyright 2016 ABB. All rights reserved.
Operation
Servicing work
Entries in engine logbook
By monitoring the engine, conclusions can be drawn about the turbo-
charger performance.
The following operating data and measured values must be entered regu-
larly in the engine manufacturer's engine logbook:
€ Engine performance and speed
€ Air intake temperature
€ Exhaust gas temperature in front of and behind the turbine
€ Pressure of charge air
€ Pressure drop in charge air cooler
€ Lubricating oil pressure and lubricating oil temperature
€ Air temperature behind compressor and charge air cooler
€ Turbocharger speed
€ Pressure loss in air filter
Operation Manual / TPS44-F.. - TPS61-F..