ABB HT563800 Operation Manual page 64

Turbocharging
Table of Contents

Advertisement

NOTICE
5.3.2
CAUTION
CAUTION
CAUTION
NOTICE
© Copyright 2015 ABB. All rights reserved.
Maintenance
Turbine cleaning during operation
Choice of cleaning method
If you need information about the choice of cleaning method (short /
long), you can contact the engine builder or an official ABB
Turbocharger service station.
Prerequisites
Risk of corrosion and deposits
Impairment and damage of turbocharger by salt water and cooling
water additives in flow ducts
Don't use salt water for cleaning, but only clean fresh water.
Avoid corrosion on casing inner surfaces.
Let engine run for 10 minutes after wet cleaning.
Maximum temperature in front of turbine during cleaning
When cleaning, the temperature in front of the turbine will rise and can
heavily stress the material of turbine components. The temperature at
the turbine inlet can be up to 100 °C higher than the exhaust gas
temperature after the cylinder. This should be taken into consideration
when setting the operating point before cleaning.
Don't exceed maximum temperature in front of turbine when
cleaning.
Impermissible thermal stressing and flooding of the turbine
Smaller volumes of water can result in poor cleaning. Larger volumes of
water lead to impermissible thermal stressing of the turbine
components and can cause flooding of the turbine.
Be absolutely sure to observe turbine cleaning parameters.
V-engines
In the case of V-engines with several turbochargers on each engine, we
recommend parallel cleaning of both turbochargers. This cleaning
process is faster and the risk of turbocharger surging is reduced.
Operation Manual / TPS44-F.. - TPS61-F..
5
5.3
Page 62

Advertisement

Table of Contents
loading

Table of Contents