Remove The Service Panel. (See Photo 1) (2) Remove The Top Panel. (See Photo 1) (3) Remove The Electrical Parts Box. (See Photo 4) - Mitsubishi Electric Mr. Slim PUHZ-ZRP35VKA Service Manual

Split-type, heat pump air conditioners outdoor unit
Hide thumbs Also See for Mr. Slim PUHZ-ZRP35VKA:
Table of Contents

Advertisement

OPERATING PROCEDURE
10. Removing the high pressure switch (63H)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the electrical parts box. (See Photo 4)
(4) R emove 3 right side panel fixing screws (5 × 12) in the
rear of the unit and remove the right side panel.
(5) Pull out the lead wire of high pressure switch.
(6) Recover refrigerant.
(7) Remove the welded part of high pressure switch.
Note 1: Recover refrigerant without spreading it in the air.
Note 2: The welded part can be removed easily by
removing the right side panel.
Note 3: When installing the high pressure switch, cover it
with a wet cloth to prevent it from heating (100°C
or more), then braze the pipes so that the inside
of pipes are not oxidized.
11. Removing the reactor (ACL)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the electrical parts box. (See Photo 4)
(4) R emove 3 reactor fixing screws (4 × 16) and remove the
reactor.
Note: The reactor is attached to the rear of the electrical parts
  box.
OCH527C
PHOTOS
Photo 9
Lead wire of
high pressure switch
Photo 10
Reactor fixing screw
Reactor fixing screws
134
High pressure switch (63H)
Reactor
(ACL)
Electrical parts box

Advertisement

Table of Contents
loading

Table of Contents