OPERATING PROCEDURE
Photo 3
Screws
of the
electrical
parts
2. Removing the fan motor
(1) Remove the top panel, the service panel, and the front panel
(Photo 1).
(2) Disconnect the connector CN931 and CN932 on the outdoor
electronic control P.C. board.
(3) Remove the propeller.
(4) Remove the fan motor.
3. Removing the 4-way valve
(1) Remove the top panel (Photo 1).
(2) Remove the service panel, rear panel, and pipe cover.
(3) Recover gas from the refrigerant circuit.
NOTE:
Recover gas from the pipes until the pressure gauge
shows 0 kg/cm
2
(0 MPa).
(4) Remove the electrical parts (Photo 3).
(5) Detach the brazed parts of 4-way valve and pipe.
Photo 4
Suction
pipe
brazed
part
Discharge
pipe
brazed
part
Photo 5
Screws of the outdoor fan motor
Propeller
Propeller nut
Separator
Photo 6
84
PHOTOS
Compressor nuts (3 places)
Sound
proof felt
4 way valve
R.V. coil
Brazed parts