OPERATING PROCEDURE
(2) Remove the top panel. (See Photo 1)
more), then braze the pipes so that the inside of
(4) Remove 3 valve bed fixing screws (4 × 10) and 4 ball
(5) Remove 3 right side panel fixing screws (5 × 12) in the
rear of the unit then remove the right side panel.
(7) Recover refrigerant.
Note 2: The welded part can be removed easily by
removing the right side panel.
oxidized.
OCH527C
ILLUSTRATIONS
Figure 1 (PUHZ-ZRP100-125VKA)
Valve bed
(PUHZ-ZRP140VKA)
Valve bed
138
4-way valve
coil (21S4)
4-way valve
Thermistor
<Outdoor pipe>
(TH33)
LEV coil
(LEV B)
LEV coil
(LEV A)
Ball valve
Stop valve
LEV coil
(LEV C)
LEV coil
(LEV B)
Thermistor
<Outdoor pipe>
(TH33)
LEV coil
(LEV A)
Ball valve
Stop valve

Advertisement