Dacor Epicure EG366SCH Installation Instructions Manual page 9

Dacor epicure eg366sch: install guide
Hide thumbs Also See for Epicure EG366SCH:
Table of Contents

Advertisement

2 5/8"
(67 mm)
1/2" (13 mm)
countertop
overhang
C L
24 5/8"
15"
(625 mm)
(381 mm)
11 7/16"
(291 mm)
Cabinet/Countertop Cutout Dimensions with Raised Vent - Top View
3/8" Min. (10 mm)
space behind
raised vent
chassis to clear
stiffener
Dacor approved
raised vent
Installation Requirements
3/8" (10 mm) Min.
countertop overhang
Open to below to allow for raised
vent, gas and electrical connections
1" thick mounting platform Min.
Hole 1/2" dia. (13 mm),
2 places, through platform
for hold down bolts
D
C L
3/8" Min. (10 mm)
flat countertop overhang
required behind cutout
Stiffener
Cabinet/Countertop with Raised Vent - Side View
Non combustible rear
wall recommended
E
D
C L
B
NOTE: Gas and electrical connections may only be routed through
the bottom of the cooktop when installed with a raised vent.
Countertop
EG366 or EG486 cooktop
Control panel
Cabinet face
IMPORTANT: See raised vent
installation instructions for
duct system layout/planning
10" (254 mm) Min. to
combustible wall
above countertop,
both sides
1/2" (13 mm)
countertop
overhang
2" (51 mm)
1" (25 mm)
Cabinet face
below countertop
C L
overhang
Minimum
countertop
height:
30 1/4"
(768 mm)
7