Brant Radiant Heaters DX3L Series Manual page 7

Gas-fired infrared tube heater
Table of Contents

Advertisement

DX3L
Series
F/N: LLTB026
SERVICE ACCESS PANEL
FAN COMPARTMENT
COMPARTIMENT VENTILATEUR
1. Disconnect gas & electricity.
1. Débrancher le gaz et l'electricité.
2. Remove top cover
2. Retirer les 2 vis à main du couvercle
(2 thumbsscrews).
supérieur.
3. Remove six (6) 1/4" screws.
3. Retirer les 6 vis 1/4 po.
4. Soulever et retirer le panneau.
4. Lift and remove panel.
GARDER LE COUVERCLE EN PLACE. NE L'ENLEVER QUE POUR L'ENTRETIEN.
F/N: LLTB025R
Fan Compartment
Lighting /Shut Down Instructions Label
SERVICE ACCESS PANEL
F/N: LLTB024L
RE-VERBER-RAY LOW INTENSITY INFRARED HEATER
RADIATEUR A INFRAROUGE A FAIBLE INTENSITE
FOR INDOOR INSTALLATION ONLY. NOT FOR USE IN RESIDENTIAL DWELLING.
INSTALLATION À L'EXTÉRIEUR SEULEMENT. NE PAS INSTALLER DANS UN LOGEMENT.
MODEL /MODELE NO.
INPUT BTU/H
FOR USE WITH
HL3-40-125N
125,000/95,000
NATURAL GAS
HL3
VOLTS A.C.
MANIFOLD PRESSURE
HEATER TYPE
120~60Hz
3.5" WC
C1
VERSION
STARTING AMPS.
MIN. INLET PRESSURE
4.8
5.0" WC
10/11
RUNNING AMPS.
ORIFICE SIZE
MIN. MOUNTING ANGLE:
1.1
#3 D.M.S
0 DEGREES
COMBUSTION CHAMBER:
FOR STAINLESS STEEL UPGRADES THE
MAX. MOUNTING ANGLE:
COMBUSTION TUBE IS UPGRADED TO 409
4" BC ALUMINUM
45 DEGREES
STAINLESS STEEL.
ANSI Z83.20b - 2011 CSA 2.32b - 2011 Low - Intensity Infrared Htr.
FOR INDOOR USE
ANS Z83.20b - 2011 CSA - 2011 Low - Intensity Infrared Htr.
BRANT RADIANT HEATERS LIMITED
SERIAL NO.
34 SCOTT AVE., PARIS, ONTARIO
0870 XXXX XXXX 0001
TEL: 1-519-442-7823 WWW.BRANTRADIANT.COM
Controls Compartment
16" Burner Tube
1.0
Introduction
RE-VERBER-RAY LOW INTENSITY INFRARED HEATER
RADIATEUR A INFRAROUGE A FAIBLE INTENSITE
FOR INDOOR INSTALLATION ONLY. NOT FOR USE IN RESIDENTIAL DWELLING.
INSTALLATION À L'EXTÉRIEUR SEULEMENT. NE PAS INSTALLER DANS UN LOGEMENT.
MODEL /MODELE NO.
DX3L-40-125N
VOLTS A.C.
120~60Hz
STARTING AMPS.
4.8
RUNNING AMPS.
1.1
COMBUSTION CHAMBER:
4" BC ALUMINIZED
ANSI Z83.20b - 2011 CSA 2.32b - 2011 Low - Intensity Infrared Htr.
ANS Z83.20b - 2011 CSA - 2011 Low - Intensity Infrared Htr.
BRANT RADIANT HEATERS LIMITED
34 SCOTT AVE., PARIS, ONTARIO
TEL: 1-519-442-7823 WWW.BRANTRADIANT.COM
Combustion Chamber
(150,000 BTU/H models and greater)
7
Safety Signs and Labels
Rating
Plate
INPUT BTU/H
FOR USE WITH
125,000
NATURAL GAS
MANIFOLD PRESSURE
HEATER TYPE
3.5" WC
C1
MIN. INLET PRESSURE
VERSION
5.0" WC
10/11
ORIFICE SIZE
MIN. MOUNTING ANGLE:
0 DEGREES
#4 D.M.S
FOR STAINLESS STEEL UPGRADES THE
MAX. MOUNTING ANGLE:
COMBUSTION TUBE IS UPGRADED TO 409
45 DEGREES
STAINLESS STEEL.
FOR INDOOR USE
SERIAL NO.
0870 XXXX XXXX 0001
Radiant Tube(s)
Yellow Titanium Alloy Tag