Yokis MTR2000ERX Manual page 9

Radio: 2000w timed
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
MODULE CONFIGURATION TABLE
(1) Short presses sequence on pushbutton.
(2) Confirmation with flashes or relay clicks at the end of short presses sequence.
(3) Toggles the ON/OFF function (between activation and deactivation)
(4) The time may be set in minutes (default) or in seconds.
FUNCTIONS
Time configuration: Timing is off by default. All configurations are saved in the case of blackout. The on
time can be configured from 2 seconds to 4 hours by means of short presses sequences (See table). 25
short presses will set the time in seconds (from 2 seconds to 4 minutes): (reply: 5 flashes). 26 short presses
will return to a timing in minutes (from 2 minutes to 4 hours) (reply: 6 flashes).
extended time: "extended time" is off by default. 29 short presses will activate the "extended time"
function. The light will be switched on for 12 hours when a connected pushbutton is pressed for longer than 3
seconds. Short press once to switch it off before the time has passed. The module will resume normal
operation after switch-off (with the set time).
Warning: Warning is off by default. 24 short presses will activate the warning function. The light will flash
briefly one minute before the switch-on time expires (10 seconds if the time was programmed in seconds).
The pushbutton can be pressed again before the light goes out to extend the switch-on.
Current state memory in case of blackout: The current state of the relay may be saved in case of blackout
to restore the state when power is restored. 28 short presses will do this. The contact will remain open if the
relay was at rest (open) before the blackout. Otherwise it will close.
DIRECT MODE RADIO CONNECTION
1. Step 1:
5 short presses of the push button to be connected to the transmitter.
The transmitter LED will start flashing for 30 seconds, indicating that the system is waiting for a connection.
2. Step 2
While the transmitter LED is blinking, use a pointed and properly insulated tool to press the receiver
"connect" hole shortly (in the back of the container).
The receiver relay will flash once and the transmitter LED will stop flashing if the connection was successful.
Warning: the receiver must be powered up.
To delete a connection: repeat the procedure above.
DS1054-012F
------ function configuration -------
Number of
Function
Presses (1)
20
Local control from switch (3)
21
Lock configurations
22
Flashing mode (3)
Unlock configurations (with automatic
23
lock after one hour)
24
Enable switch-off warning (3)
25
Set time in seconds (4)
26
Set time in minutes (4)
27
Timer/Relay Mode
Enable memory status in case of
28
blackout (3)
29
Enable extended time (3)
30
Full reset to default settings
P9
Reply (2)
10 flashes
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes
9 flashes
2 flashes

Advertisement

Table of Contents
loading

Table of Contents