Yokis MTR2000ERX Manual page 8

Radio: 2000w timed
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
RADIO: 2000W TIMED RELAY MODULE
MTR2000eRX
5454455 Radio: 2000W Timed Relay with Aerial
MTR2000eRP
5454462
MTR2000eRPX 5454463
Functions
This module may be used in wireless mode and by one or more
additional local pushbuttons.
Technical Specifications
Mains voltage:
Power on resistive load: Max. 10A 2000W
Module consumption:
Radio frequency:
Sound level:
Ambient temperature:
Relative humidity:
Dimensions:
Special features of the MTR2000eR:
Switches may be used instead of pushbuttons with the MTR2000ER receiver (an E2BP transmitter must
be used).
To establish a connection, switch 5 times rapidly (not 10!), instead of 5 pulses. Simply repeat the connection
procedure with 5 pulses to use a pushbutton instead of the switch again.
WIRING
230V ~
N L
10A
230V ~
(*) Contact an Urmet retailer or go to www.yokis.com for information on availability
DS1054-012F
Radio: POWeR 2000W Flush-mounted
Timed Relay
Radio: POWeR 2000W Flush-mounted
Timed Relay Module with external Aerial
230V
+10% -15% - 50Hz
~
< 1VA - < 0.3W
2.4GHz
<60dB a 20 cm
from -20°C to +40°C
0 - 90%
48 x 33 x 22.5 mm
[1.96 x 1.30 x 0.88"]
P1
Optional pushbuttons
Pulsanti opzionali
RAdIO RANGe
Standard Range:
• In the same room (< 100 m²)
• 50 m in open range
POWeR Range (*):
• Inside 100 m² apartments with
perpendicular crossing of main wall or
ceiling
• 250 m in open range
(Note: in both cases the range may be
reduced by the presence of metallic
elements, crossing of walls, or partitions)
RAdIO TRANSMISSION
The transmitter Led will light up only if
the radio transmission was successful.
Adding an intermediate receiver will solve
the problem of an insufficient range.
Refer to the transmitter instruction booklet
for more information.
P2
P8
GB
Installing Cautions
The module must be installed only by qua-
lified personnel and into a place the end-
user cannot access, according to the
installing national rules.
In order to follow the safety rules, the
module must be connected to a power line
that is upstream protected by a magneto-
thermic switch 10A C curve.
Except MTV500ER, for all other YOKIS
radio receiver modules you must use a
pointed and properly insulated tool to
press the "connect" hole shortly.
IMPORTANT:
Before starting any configuration, press
briefly 23 times to unlock the relay.
The module will lock again
automatically after 6 hours.
It can also be locked immediately with
21 short presses.

Advertisement

Table of Contents
loading

Table of Contents