Section 1 – Introduction Precautions • Please check the packaging and appearance after you received the product. • Please check the mode and specification of the product. Keep correct electrical connection and mounting method. • Please installation WITHOUT power. • During using, please notice the technical and operation conditions: the temperature of medium, burst pressure, power supply.
Section 2 – Setup 2.1 General Dimensions Section 3 – Menu and Configuration 3.1 LCD and Code Description CODE DESCRIPTION kPa PSI Kg/cm² Bar Mpa Pressure Unit MAX/MIN Max/Min Pressure Battery Level Percent Communication Sign Abnormal sensor communication or sensor damage Current Pressure Over Range Use or Sensor Damage Enter pressure calibration procedure, please power off and exit Enter Temperature Compensation Procedure, Please Turn Off and Exit...
3.2 Button Functionality BUTTON NAME DESCRIPTION POWER Short press to turn ON/OFF UNIT Short press to switch pressure units Short press to turn on the backlight; long press to keep the BACKLIGHT backlight on ZERO Press for 4 seconds to zero clearing Adjust of Filter Constant Short press ‘back-light’...
3.6 Peak Value Long press ‘UNIT’ button for 4 seconds, the screen will show the Maximum value after last zero clearing, then press ‘UNIT’ button , it will show Minimum value, then press ‘ UNIT’ button to quit. During show Max or Min value, long press ‘ZERO’ button to clear record before, and enter a new record. Troubleshooting Question: Back-light Dim...
Section 4 - Software Instructions 4.1 Software Instructions ⅰQuick start 1. Plugin the USB adaptor. Extract the software package to you desire folder. Click “Omega DPG280 DataCenter.exe” to start the application. “dot net Framework 4.8” should be install if the software cannot start. This installation has been placed in the drivers folder.
Page 8
3. Select the unit and click “download” button to start the download process. 4. Drag the data chart to zoom in the curve, right click to zoom out. 5. Click the “Export” button to export the history data. UNRESTRICTED...
Page 9
6. Click the “Clear” button to clear the history data in gauge. ⅱ Diver install 1. Right click the “This computer” and select “manager” 2. Right click the exclamatory marked USB device and select “update driver”. Click “Browse this computer to find the driver”.
Page 10
WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.