5 16 Scenes (only for hot tubs equipped with said settings)
Scenes are packages of function presets. They can be used to save preferred hot tub
settings of different users.
How to create a scene setting
a)
Turn on the preferred hot tub functions you would like to save to a scene setting.
b)
Enter the scene settings in the main menu and select the chosen number for the scene.
c)
Save the scene by holding the middle button.
d)
Scene saved will show up on the screen.
6

Trouble shooting

Most of the messages show up in the lower left corner of the screen.
GENERAL REPORTS
The water temperature is unknown
– – °F – – –°C
The current temperature will show up after 1 minute of the circulation
pump running.
Show up when conditions of possible water freezing are detected or the
conditions
AUX freeze switch has turned off while the circulation pumps and jets are
of possible
turned on. In some cases the circulation pumps can turn on and off and
freezing
the heater can run in the freeze protection mode. This is an informative
operational message, not a defect indicator.
The water is too hot
One of the temperature sensors detected a water temperature of 109.94 °F
and the hot tub functions are disabled. The system will automatically
M029
rest once the water temperature falls under 107.96 °F. Check whether
the circulation pump has been running for too long or the surrounding
temperature is too high.
HEATER REPORTS
The water flow through the heater is reduced
This report says that not enough water flows through the heater for the
M016
warmth from the heater to get effectively distributed. The heater will
turn on again after approximately 1 minute. See below for "Checking the
water flow".