Recommended Mounting Plate Retention Spots And
Dimensions
20/25/35J
«
Recommended mounting plate
retention spots (5 spots in all)
166
54.5
153.8
263
51.9
Liquid pipe end
20/25/35J (ALTERNATIVE INSTALLATION PLATE)
Recommended mounting plate retention spots
(5 spots in all)
104
153
52
55
207
Liquid pipe end
Gas pipe end
50/60J
«
Recommended mounting plate retention spots
(7 spots in all)
190
Liquid pipe end
45
91
Gas pipe end
580
45
1065
Hole With Cone Drill
Inside
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Use tape measure as shown.
Position the end of a tape measure at
184
Through the
wall hole
Ø 65mm
181.7
55.5
Drain hose
800
position
Gas pipe end
All dimensions are in mm
141
Through the
wall hole
Ø 65mm
Drain hose
position
181
56
800
All dimensions are in mm
173
Through the
wall hole
Ø 65mm
Drain hose
219
48
position
All dimensions are in mm
Outside
Caulking
Ø 65
Wall embedded pipe
(Field supply)
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the installation
plate (Engage the two hooks at the rear top of the indoor unit
with the upper edge of the installation plate). Ensure that the
hooks are properly seated on the installation plate by moving
Ñ
it to the left and right.
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front grille)
to release the claws.
Front grille
Hang indoor unit's hook here.
When stripping the
ends of interconnecting
wires in advance, bind
right ends of wires with
insulating tape.
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for
smooth drainage. Avoid situations that are likely to cause
water to leak.
Water Drainage
Water
leaking
Correct
Wrong
• Do not install the unit at altitude over 2000m for both
1-8
www.mrklimat.ru
Тел.: 8-800-5555-710
Mounting plate
Bottom frame
Mark (rear side)
Mounting plate
Interconnecting
wires
Wire guide
Water
Retention
Water
Water
leaking
leaking
Wrong
Wrong
! CAUTION
indoor and outdoor.
Clip
End dipped
into water
Drain