[CAC FILE(SD CARD)]
[LOAD]
[DELETE]
[LENS FILE(SD CARD)]
[LOAD]
[SAVE]
[SAVE AS]
[LENS FILE(MEMORY)]
[LOAD]
[SAVE]
[CLEAR ALL FILE]
[SLOT FOR LOAD/SAVE]
Sets the card slot to load and save the scene file, setup file, CAC file, lens file, and streaming setting file.
The items that can be set are as follows.
f [SLOT2], [SLOT3]
(Factory setting: [SLOT2])
[BATTERY]
[DC IN SOURCE]
Sets the type of external power supply to input to the <DC IN> terminal.
The items that can be set are as follows.
[DC POWER SUPPLY]
[BATTERY]
(Factory setting: [DC POWER SUPPLY])
[DC IN BATTERY]
[FULL VOLT]
[NEAR END VOLT]
[END VOLT]
[ONBOARD BATTERY]
[BATTERY SEL]
[FULL VOLT]
[NEAR END VOLT]
Chapter 4 Operation — Menu settings
Selects the chromatic aberration compensation data file saved in the memory card and loads it into the camera.
Specifies the file number to save the chromatic aberration compensation data loaded from the memory card with [LOAD] into
the camera.
Selects and deletes the chromatic aberration compensation data file saved in the memory card.
Selects a lens file saved in the memory card, and loads it as one set of lens files (8-file set) into the camera memory.
Overwrites a file selected from the list of lens files saved in the memory card with the one set of lens files (8-file set) in the
camera memory.
One set of lens files (8-file set) in the camera memory is saved in the memory card as a new lens file by entering a file name.
Selects the lens file saved in the camera memory, loads it, and uses it as current setting value for the operation.
Current setting value is saved in the camera memory as a lens file by specifying the title and the file number.
Clears and initializes saved values for all the lens files.
Select when connecting the AC adaptor.
Select when connecting the battery.
Voltage to display full/near end/end remaining capacity can be set in the [OTHERS] menu → [BATTERY] → [DC IN
BATTERY].
Sets the voltage to display full remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f [13.0V] ... [17.0V] (0.1 V steps)
(Factory setting: [15.5V])
Sets the voltage to display near end remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f [11.1V] ... [15.0V] (0.1 V steps)
(Factory setting: [13.2V])
Sets the voltage to display end remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f [11.0V] ... [14.9V] (0.1 V steps)
(Factory setting: [12.5V])
Select according to the used battery.
When set to [DIONIC], [HYTRON/TITON], [ENDURA], or [PAG], remaining capacity is detected and the warning is displayed
according to the [NEAR END INFO] or the [END INFO] setting.
The remaining capacity is detected by the voltage level when set to [other].
When there is no remaining capacity information, the remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [DIONIC], [HYTRON/TITON], [ENDURA], [PAG], [other]
(Factory setting: [DIONIC])
Sets the voltage to display full remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [13.0V] ... [17.0V] (0.1 V steps)
(Factory setting: [15.5V])
Sets the voltage to display near end remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [11.1V] ... [15.0V] (0.1 V steps)
(Factory setting: [13.2V])