    • Check accessories and connection parts for possible damage prior to every use of the device. Do not use any Follow the manual defective devices or device parts. Information marked with this symbol indicates that the instructions must be observed. dehumidifier TTK Qube...
  • Page 3 • The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air- conditioning or by Trotec. dehumidifier TTK Qube...
  • Page 4 A air-conditioning or by Trotec. corresponding repair manual is available from the manufacturer upon request. dehumidifier TTK Qube...
  • Page 5: Information About The Device

    1. Switch off the device. 2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket. 3. Do not reconnect a defective device to the mains. dehumidifier TTK Qube...
  • Page 6: Transport And Storage

    • with a cover to protect it from invasive dust, if necessary Air filter • stackable: up to 4 devices may be stacked on top of one another • Place no further devices or objects on top of the device to prevent it from being damaged. dehumidifier TTK Qube...
  • Page 7: Assembly And Installation

    • When positioning the device, particularly in wet areas, Technical annex. secure it locally with an RCD (residual current device) which complies with the respective regulations. dehumidifier TTK Qube...
  • Page 8 1. Connect the condensation drain hose to the hose connection. Connecting the power cable • Insert the mains plug into a properly secured mains socket. 2. Make sure that the condensation drain hose is properly connected to the device and free of damage. dehumidifier TTK Qube...
  • Page 9: Operation

    • Avoid open doors and windows. factory-calibrated and may be used for accounting purposes. • After being switched on, the device operates fully Contact your Trotec customer service. automatically. Switching the device on • The compressor switches on approx. 3 minutes after the device has been switched on.
  • Page 10: Available Accessories

    This feature protects the device from Designation Article number overloading since high temperatures and high humidity levels Air filter for TTK Qube 7.160.000.014 expose the device to extreme stresses. Moreover, drying is no longer economical at such high temperatures and also poses Condensation drain hose 7.331.000.474...
  • Page 11: Errors And Faults

    • From the outside, check the condenser for dirt (see or to Trotec for repair. chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec. • The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
  • Page 12: Maintenance

    10. Date: .......... 11. Date: ........... 12. Date: ........... Signature: ........Signature: ......... Signature: ......... Signature: ......... 13. Date: ......... 14. Date: .......... 15. Date: ........... 16. Date: ........... Signature: ........Signature: ......... Signature: ......... Signature: ......... dehumidifier TTK Qube...
  • Page 13 3. Check the inside of the device for dirt. companies or by Trotec. 4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air- Running capacitor conditioning or by Trotec.
  • Page 14 5. Reassemble the housing on base frame and cooling system. Finally retighten all screws. 3. Allow the filter to dry completely. Do not insert a wet filter into the device! 4. Reinsert the air filter into the device. dehumidifier TTK Qube...
  • Page 15: Technical Annex

    Sound pressure level LpA (1 m; 53 dB(A) complies with DIN 45635-01-KL3) Dimensions (length x width x height) 315 x 382 x 340 mm Minimum distance to walls and other objects A: top: 5 cm B: rear: 50 cm C: side: 5 cm D: front: 50 cm Weight 16 kg dehumidifier TTK Qube...
  • Page 16 Wiring diagram With operating hours counter and MID-compliant energy meter dehumidifier TTK Qube...
  • Page 17 Water Pan to Condensates Pump Hose Controls' Sticker Non-Marking Rubber Feet Condensates Pump Supply Cable Compressor Condensates Pump baseplate Cable Retainer Running Capacitor Condensates Pump to Fitting Hose I/0 Main Switch + Status LED Defrost Valve Condensates Outlet Fitting dehumidifier TTK Qube...
  • Page 18: Disposal

    Declaration of conformity in accordance with the EC Machinery Directive 2006/42/EC, Annex II, Part 1, Section A Herewith, we – Trotec GmbH– declare that the machinery designated below was developed, constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006/42/EC.