Maintenance and care
Empty the pump and all water pipelines at temperatures around the freezing point completely.
Frozen water can harm the pump and the water pipelines!
With all maintenance work and trouble shootings,
with which the device must be tip, the angle of
inclination may not exceed >30°.
6.3
Trouble shooting
ERROR
Engine does not start.
Engine runs but no pressure is
produced.
Engine runs, pressure is produced,
but no turn of the rotation arm
Engine runs, pressure is produced,
rotation arm turns, but no cleaning
effect
CAUSE
●
Error at the engine
●
Spray gun produces back
pressure
●
No water supply
●
Circle swing assembly faulty
●
Nozzle clogged
●
Error in the pump
●
The rotation arm is obstructed
●
Nozzle position is not correct.
●
Nozzles are clogged (caused by
a sand grain )
REPAIR
●
See operating instructions of the
engine (Appendix)
●
When starting press pistol on
spray gun
●
Check water supply
●
Check circle swing assembly
●
Check nozzle
●
See operating instructions pump
(Appendix)
●
Repair error when device is shut
down.
●
Correct Nozzle position (~20°)
with pipe tongs (see Fig. 1).
●
Correct Nozzle position (~20°)
with pipe tongs (see Fig. 1).
●
Remove nozzles and clean them.
14 / 16