Operation

5
Operation
5.1

General

The pump may not be operated in the dry operation (without water supply)!
The pump may be operated with lance/jet tube max. 5 minutes continuously, without water outlet.
In order to avoid damage to the device (EC-60), the water temperature (water inlet) may not exceed 40° C.
The supply water from the line system must be filtered with 300-400 µ. The water pressure may amount to max.
10 bar. A minimum water pressure of 0,3 bar (at 20 l/min) is necessary, otherwise no function of the engine!
If supply water is taken out of a well, or an open waters, it must be filtered with 100-200µ.
Do not drive with the equipment over uneven area/supernatant articles! Rotation arm/nozzles can be
damage/adjusted!
General it is forbidden to grip under rotary parts - danger of injury!
1.
Open the handles of the device
2.
Open main top (pic. 1a/pic. 1)
!
Important: open absolutely first the water
supply (main tap) before starting the engine!
(Pic. 1a /Pic. 1) 
Close the cross flow (Pic. 4) while starting the
engine.
In case of starting problems of the engine (often
in cold weather) unscrew pressure adjusting
valve () (anticlockwise). Once the engine is at
operating temperature, screw in the pressure
adjusting () valve (clockwise).. (Pic. 1B) 
(See chapter Installation)
1
Main tap
Pic. 1A
10 / 16
Pic.
Pic. 1B