PLEASE READ THIS MANUAL BEFORE ATTEMPTING TO OPERATE EQUIPMENT!!
1. Carefully lift the amplifier by the bottom cabinet edge out of the shipping carton. Place the
amplifier on a firm, level surface and carefully inspect it for shipping damage. Contact the
shipper immediately if any damage exists. Save the carton and packing material for possible
shipping in the future.
2. Remove the twelve screws holding the cover on with a number 2 phillips screwdriver.
Carefully lift the cover off the amplifier. Save the screws to rescuer the cover. Note that the
AL811H is shipped with the fuses and fuse caps inside the amplifier.
3. Locate the fuse pack with the two 12 ampere fuses and fuse caps. If additional screws are
needed, they will be in the fuse pack also. NOTE: Fuses supplied are for 120/110/100V
operation (Models AL-811H/HY). If you are rewiring the AL-811H for 240/230/220V
operation, you must use 8 ampere fuses. The AL-811HX export model is pre-wired for
240V operation and is supplied with 8 ampere fuses.
4. Remove the foam packing material (around the tubes) that secures the 811A tubes during
transit. Carefully unwrap the tubes. Do not dislodge or break the shaft that is connected to
the rear input bandswitch wafer.
5. To install the tubes in the sockets, be sure the large diameter pins line up with the two large
diameter holes in each socket. Do NOT rock or twist the tubes excessively during the
installation. If the tubes are already installed, check them for proper seating. If necessary,
press the tubes down into their sockets with gentle force. Do not rock or twist the tubes
excessively. Also, check that the anode caps are secure and that they did not come loose
during the unwrapping process.
6. The white ceramic anode connector will have to be removed from the top metal cap of each
tube if it ever becomes necessary to remove the tubes from the amplifier. This can be a
difficult procedure because the high clamping force of the internal springs in the anode
connector may hold it to the cap very tightly. The tube will break if direct upward or rocking
pressure is applied in an attempt to remove the connector. The safest way to remove the
ceramic connector is to lift the tube out of its socket. A twisting or spinning pulling motion
can then be applied while holding the ceramic connector firmly until the tube and connector
are separated. Repeat the procedure with each tube.
7. Install the cover with the vent holes to the left (near the tubes) by installing the back screws
first. Install all the screws loosely and tighten them only after all the screws are in place.
8. Install the fuses and fuse caps on the back of the unit. Read the manual to become familiar
with the operation of the AL-811H amplifier.
UNPACKING INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AL-811HY and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AMERITRON AL-811HY

  • Page 1 PLEASE READ THIS MANUAL BEFORE ATTEMPTING TO OPERATE EQUIPMENT!! UNPACKING INSTRUCTIONS 1. Carefully lift the amplifier by the bottom cabinet edge out of the shipping carton. Place the amplifier on a firm, level surface and carefully inspect it for shipping damage. Contact the shipper immediately if any damage exists.
  • Page 2 Export model(AL-811HX/HY): 160, 80, 40, 30, 20, 17, 15, 12, The AL-811H is a grounded grid linear amplifier developed by and 10 meter bands. Ameritron using low cost 811A power triodes. It operates in class AB2 for SSB and CW. Input...
  • Page 3: General Information

    This voltage should be used to limit the exciter mail, please allow at least three weeks for a written reply. AL-811H for exciters that drive to safe drive levels for the AMERITRON develop more than 116 Willow Road 70 watts of output power.
  • Page 4: Installation

    METERING FUNCTIONS If the current is too low, the loading control should be turned to The AL-811H has two illuminated panel meters. The right a lower setting. The left meter reads PA high voltage up to 2000 meter reads PA grid current up to 200mA. The normal current volts and plate current up to 750mA.
  • Page 5 INTERCONNECTIONS Connect the RF output of the transmitter or transceiver to Connect the shortest possible ground lead from a good earth the RF IN connector on the rear of the AL-811H with 50 ground to the GND terminal. The best leads are solid ohm coax.
  • Page 6 TUNE-UP CW PROCEDURE Follow the instructions in numerical order. If the various meter With the exciter drive still at zero, place the METER/HV- readings are different than those indicated in the instructions, Ip switch in the Ip position. Observe the 750mA scale. It check the connections from the exciter to the amplifier and make should read zero.
  • Page 7 IMPORTANT ADDITIONAL INFORMATION Authorized dealer: http://www.classicinternational.eu...
  • Page 8 Authorized dealer: http://www.classicinternational.eu...
  • Page 9: Qsk Operation

    Ameritron for details on the QSK-5. standard conventional relay effectively. Ameritron offers a high The AL-811H will operate with full output on all WARC bands except 24.5 MHz The AL-811HX/HY will operate with full output on all WARC bands...
  • Page 10: Periodic Maintenance

    PERIODIC MAINTENANCE connect a jumper wire from ground to the anode connection of The high voltage present on the plate choke and air variable the tubes. NOTE: This is a safety wire that must be installed capacitors attract dust and dirt out of the air stream. It is when beginning service work and must be removed when particularly important that the high voltage areas at the bottom...
  • Page 11 Power supply shown wired for 120V operation *...
  • Page 12: Parts List

    6.75T (405-1067) 150 (208-5396) 10/12 180 (208-5605) 4.75T (405-1047) 100 (208-5174) PARTS LIST Designation Description Ameritron Part # 410-3583 C1, 2, 21, 22 0.01 uF, 250VAC/1.4KVDC Dis. 200-2122 C3, 4 See Input Chart C5, 7, 19, 37 0.01 uF, 50V Disc 200-0416 2200 uF, 25V Elec.
  • Page 13 8 Amp (240 Vac Operation) 755-1432...