Cob exterior fixture

Advertisement

Quick Links

Endura WW100 COB
Exterior Fixture
User Manual
Order code: ELUM458

Advertisement

loading

Summary of Contents for Elumen8 Endura WW100

  • Page 1 Endura WW100 COB Exterior Fixture User Manual Order code: ELUM458...
  • Page 2: Safety Advice

    • Always disconnect the power from the mains when product must be installed by a qualified technician in equipment is not in use or before cleaning! Only handle accordance with local territory regulations. The safety of the power-cable by the plug. Never pull out the plug by the installation is the responsibility of the installer. The pulling the power-cable. fixture presents risks of severe injury or death due to fire • Make sure that the available mains supply voltage is hazards, electric shock and falls. between 100~240V AC, 50/60Hz. • Warning! Risk Group 2 LED product according to • Make sure that the power cable is never crimped or EN 62471. Do not view the light output with optical damaged. Check the equipment and the power cable instruments or any device that may concentrate the beam. periodically. • WARRANTY: Two years from date of purchase. • If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. www.prolight.co.uk Endura WW100 COB User Manual...
  • Page 3 Product overview & technical specifications Endura WW100 COB Exterior Fixture The Endura series are heavy-duty, rental ready IP rated pars made for the most demanding of applications. With flicker-free operation, thanks to a 3,600Hz refresh rate, and a multitude of colour and output options the series is perfectly suited for use in concert, TV and outdoor applications. The fixture can be controlled via DMX and provides a variety of colour macro, change, fade and strobe functions with 4 selectable dimmer curves. The fixture it is also capable of master/slave operation and is accessible via a 4 button backlit display with menu lock to prevent unauthorised setting changes. The robust IP65 rated housing features TRUE1 and 5-pin DMX inputs and outputs to facilitate a problem-free connection. • 1 x 100W warm-white COB LED • Temperature controlled fan cooled for whisper quiet operation IP65 • Beam angle: 16° • 30mm snoot included • 6,070 Lux @ 2m (full on) • 3.6kHz refresh rate • DMX channels: 1 or 3 selectable Specifications Endura WW100 COB • Manual and master/slave modes Power consumption 105W • 0 - 100% 8 or 16 bit dimming Power supply 100~240V, 50/60Hz and variable strobe Fuse T2A 250V • Bracket allows for multiple rigging or...
  • Page 4: Technical Specifications

    Technical specifications MODE ENTER 01 - LCD display 05 - IP rated 5-Pin DMX input In the box: 1 x fixture 02 - Function buttons 06 - IP rated 5-Pin DMX output 1 x PowerCON TRUE1 cable 03 - PowerCON TRUE1 input 07 - Hanging bracket & 1 x user manual 04 - PowerCON TRUE1 output 08 - Hanging bracket adjustable knob Fuse: The Endura WW100 is fitted with an internal mains (line) fuse. The fuse must only be changed by qualified personnel. Before opening the fixtures housing or changing the fuse, the fixture must be disconnected and isolated from the mains supply. Replacement cartridge fuses must be of the same type and rating (20mm Glass T2A 250V). When closing the fixture please ensure the seal is correctly positioned and free from damage to ensure the fixture is water tight and to prevent water ingress. www.prolight.co.uk Endura WW100 COB User Manual...
  • Page 5 Temp. Fixture Temperature –––°F AutoLock Auto Lock Menu Setting Op.Time ––– Fixture Run Time DFSE Default Factory Settings 1 channel mode (8 bit): Channel Value Function 000-255 Master dimmer (0-100%) 3 channel mode (16 bit): Channel Value Function 000-255 Master dimmer (0-100%) 000-255 Dimmer fine 000-255 Strobe (slow-fast) www.prolight.co.uk Endura WW100 COB User Manual...
  • Page 6: Dmx Setup

    DATA cable (DMX cable) requirements (for DMX operation): This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below. Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers. Please quote: CABL10 – 2m CABL11 – 5m CABL12 – 10m Note: DMX cable must be daisy chained and cannot be split. www.prolight.co.uk Endura WW100 COB User Manual...
  • Page 7 5-pin XLR (male) 3-pin XLR (female) Pin 1: GND (screen) Pin 1: GND (screen) Pin 2: Signal (-) Pin 2: Signal (-) Pin 3: Signal (+) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk Endura WW100 COB User Manual...
  • Page 8: Weee Notice

    WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk Endura WW100 COB User Manual...