Hawk Senator S24S Handbook

24 ghz radar (fmcw) level transmitter for solids from granulates to rocks
Table of Contents

Advertisement

Quick Links

Senator S24S
Senator S24S
Senator S24S
Senator S24S
24 GHz Radar (FMCW) Level Transmitter for solids from
granulates to rocks
© HAWK 01/2019 - Senator S24S Radar Manual v1.00 en
Handbook
Handbook
Handbook
Handbook

Advertisement

Table of Contents
loading

Summary of Contents for Hawk Senator S24S

  • Page 1 Senator S24S Senator S24S Senator S24S Senator S24S Handbook Handbook Handbook Handbook 24 GHz Radar (FMCW) Level Transmitter for solids from granulates to rocks © HAWK 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 2 IMPRINT ::::::::::::::::::::::::::::::::::::::: All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without the prior written authorisation of Hawk Measurement Systems Pty Ltd. Copyright 2019 by Hawk Measurement Systems Pty Ltd www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 3: Table Of Contents

    3.11.1 How to attach the weather protection to the device............42 3.11.2 How to open the weather protection .................. 44 4 Electrical connections 4.1 Safety instructions......................45 4.2 General notes ......................... 45 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 4 7 Service 7.1 Periodic maintenance....................118 7.1.1 General notes........................118 7.1.2 Maintenance of the O-rings for the housing covers............118 7.1.3 How to clean the top surface of the device................. 119 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 5 9.8.2 AMS menu tree (details for settings).................. 155 10 Appendix 10.1 Order code ........................158 10.2 Spare parts ......................... 163 10.3 Accessories: general items..................166 10.4 Accessories: process connection kits................ 167 10.5 Glossary ........................170 11 Notes www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 6: Safety Instructions

    HMI (LCD display BL1.31.05 ER2.0.0_ 4002905801b Manual v1.00 en option) Main and Support 4002815701f Sensor 4002859301a 1 If the device does not have the display module option, the module reference number is 4002905802a www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 7: Intended Use

    Declaration of Conformity. You can download this document free of charge from the website. All devices are based on the CE marking and meet the requirements of NAMUR Recommendations NE 21, NE 43, NE 53 and NE 107. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 8: Radio Approvals

    S24SxxxxxxxxxxxxxAxxx... PP / DN100 (4¨) Drop S24SxxxxxxxxxxxxxBxxx... PP / DN150 (6¨) Drop S24SxxxxxxxxxxxxxCxxx... PTFE / DN80 (3¨) Drop S24SxxxxxxxxxxxxxExxx... PTFE / DN100 (4¨) Drop S24SxxxxxxxxxxxxxFxxx... PTFE / DN150 (6¨) Drop S24SxxxxxxxxxxxxxGxxx... www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 9 • installation and maintenance of the TLPR equipment shall be performed by professionally trained individuals only. For data about how to install EMI/RFI shielding gaskets, refer to the instructions supplied with this accessory. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 10 Onsala 57°23’45" N 11°55’35" E Cambridge 52°09'59" N 00°02'20" E Darnhall 53°09'22" N 02°32'03" W Jodrell Bank 53°14'10" N 02°18'26" W Knockin 52°47'24" N 02°59'45" W Pickmere 53°17'18" N 02°26'38" W www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 11: And Canada

    • Connect the equipment into an outlet on a circuit different from that to which the receiver is • connected. Consult the dealer or an experienced radio/TV technician for help. • www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 12 The Director of the DRAO may be contacted at 250-497-2300 (tel.) or 250-497-2355 (fax). Alternatively, the Manager, Regulatory Standards, Industry Canada, may be contacted. The Product Marketing Name (PMN) of this device is "Senator S24x Radar series". www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 13 (T=TLPR or L=LPR) and the type of signal converter (compact (C)) TLPR device: HVIN: 24GHZ-T-C LPR device: HVIN: 24GHZ-L-C 3 FCC ID and IC number TLPR device: FCC-ID:Q6BFMCW24G74T, IC number: 1991D-FMCW24GX4T LPR device: FCC-ID: Q6BFMCW24G74L, IC number: 1991D-FMCW24GX4L www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 14: Safety Instructions From The Manufacturer

    The manufacturer reserves the right to alter the content of its documents, including this disclaimer in any way, at any time, for any reason, without prior notification, and will not be liable in any way for possible consequences of such changes. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 15: Product Liability And Warranty

    This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. Special considerations and precautions are also described in the document, which appear in the form of icons as shown below. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 16: Warnings And Symbols Used

    In general, devices from the manufacturer may only be installed, commissioned, operated and maintained by properly trained and authorized personnel. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 17: Device Description

    Antenna extensions are available for this device. These are supplied attached to the device. If the antenna extensions are too long, the device will be supplied in two parts. For more data about the assembly procedure, refer to How to attach antenna extensions on page 34 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 18: Device Description

    Accessories: For more data about general items, refer to Accessories: general items on page 166 . For more Accessories: process connection kits on page 167 data about process connections, refer to www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 19: Visual Check

    Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. Compare the material references on the side of the process connection with the order. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 20: Nameplates

    11 cQPSus electrical safety certification for the USA and Canada. Agrees with NEC and CEC requirements for installa- tion in ordinary locations. 12 WARNING! Hot surface. If the device is connected to tank that operates at high temperature, there is a risk of injury. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 21: Installation

    3 Storage temperature range: -40...+85°C / -40...+185°F • Store the device in a dry and dust-free location. • Keep the converter out of the sunlight. • Store the device in its original packing. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 22: Transport

    • Protect the signal converter from direct sunlight. If necessary, install the weather protection accessory. • Do not subject the signal converter to heavy vibrations. The devices are tested for vibration and agree with EN 50178 and IEC 60068-2-6. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 23: Pressure And Temperature Ranges

    1 The maximum process connection temperature must agree with the temperature limits of the gasket material Guidelines for maximum operating pressure For more data on pressure ratings, refer to on page 134. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 24: Recommended Mounting Position

    If there is a nozzle on the tank before installation, the nozzle must be a minimum of 200 mm / from the tank wall. The tank wall must be flat and there must not be obstacles adjacent to ¨ the nozzle or on the tank wall. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 25 Figure 3-6: There is no maximum limit to the number of devices that can be operated in the same silo There is no maximum limit to the number of devices that can be operated in the same silo. They can be installed adjacent to other radar level transmitters. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 26: Tanks With Dish-Shaped And Conical Bottoms

    If possible, install the device as shown in the illustration that follows: Figure 3-7: Tanks with dish-shaped or conical bottoms 1 Axis of radar beam 2 Minimum level reading www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 27: Mounting Restrictions

    Do not put the device immediately above equipment and obstacles in a silo or pit. This can have an effect on the performance of the device. If possible, do not install a nozzle on the silo centerline. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 28 5° PTFE Drop, DN80 (3¨) 8° PTFE Drop, DN100 (4¨) 7° PTFE Drop, DN150 (6¨) 4° PP Drop DN80 (3¨) 9° PP Drop, DN100 (4¨) 7° PP Drop, DN150 (6¨) 5° www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 29: Process Connections

    All the procedures that follow are applicable to Metallic Horn and Drop antennas. Flange connections: installation procedure Figure 3-10: Flange connections: installation procedure Ød = nozzle diameter h = nozzle height www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 30 End of the procedure. If the antenna diameter is larger than the process connection size (flange) Figure 3-11: How to attach the device if the antenna diameter is larger than the process connection size www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 31 . The maximum number of antenna extensions ¨ that can be attached to the device are: Metallic Horn antenna: 10 • PP Drop antenna: 5 • • PTFE Drop antenna: 5 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 32 24 ("Point the device in the correct direction").. • Tighten the connection to the correct torque (not more than 40 N·m / 29.5 lbf·ft). End of the procedure. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 33 Drop antennas without an antenna extension: Attach the three locking screws to the antenna Drop antennas without an antenna extension: Drop antennas without an antenna extension: with a 3 mm Allen wrench. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 34: How To Attach Antenna Extensions

    Metallic Horn antennas: Make sure that there are not more than 10 antenna extensions attached to a device with a Metallic Horn antenna. If there are more than 10 antenna extensions, the device will not measure correctly. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 35 Drop antenna. If there are more than 5 antenna extensions, the device will not measure correctly. Make sure that you put an O-ring 4 into the groove at the top of each antenna extension. Equipment needed (not supplied): • 3 mm Allen wrench www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 36 • Push [ ] or [ ] to set the screen to Yes Yes and push [^ ^ ^ ^ ] to store and use the changed settings. End of the procedure. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 37: Orientation System (Accessory)

    • Remove the antenna from the part below the flange (if there are no antenna extensions). The antenna is not attached to the device. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 38 • Remove the antenna from the part below the flange (if there are no antenna extensions). www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 39 If the antenna diameter is larger than the process connection, refer to Process connections on page 29 If it is necessary to send an order for the orientation system, refer to Accessories: process connection kits on page 167 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 40: How To Tilt The Device

    • Loosen the 4 socket head screws around the orientation system with a 5 mm Allen wrench. • Tilt the device to the correct angle. • Tighten the 4 socket head screws. This step locks the orientation system to prevent movement. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 41: How To Turn Or Remove The Display Module (Option)

    • Display extractor CAUTION! Disconnect the power supply. Follow this procedure: • Remove the housing cover with the cover wrench. • Find the two clips that hold the display module in the housing. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 42: Weather Protection

    1 Weather protection cover (with an R-clip to hold the cover on the clamp) 2 Device 3 Weather protection clamp (2 parts) 4 2 locking nuts 5 10 mm socket wrench (not supplied) The overall dimensions of the weather protection are on page 136. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 43 3 Lower the weather protection cover onto weather protection clamp until the hole for the lock is in the slot at the front of the cover. 4 Put the R-clip into the hole at the front of the weather protection cover. 5 End of the procedure. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 44: How To Open The Weather Protection

    1 Remove the R-clip from the hole at the front of the weather protection cover. 2 Remove the weather protection cover. 3 Lift the display screen cover. End of the procedure. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 45: Electrical Connections

    Devices with the PROFIBUS PA output option: Devices with the PROFIBUS PA output option: Devices with the PROFIBUS PA output option: For electrical connection data, refer to the "Description of PROFIBUS PA interface" supplementary instructions. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 46: Electrical Installation: Output Options With Cable Gland

    Use the applicable electrical cables with the cable glands. • Make sure that the current is not more than 5 A or that there is 5 A-rated fuse in the • electrical circuit that energizes the device. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 47 • Cover wrench Procedure 1 Loosen the lock screw with a 3 mm Allen wrench. 2 Remove the cover stop. 3 Turn the cover counterclockwise with the cover wrench. 4 Remove the cover. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 48 1 Loosen the cable gland. Put the electrical wires into the cable entry. Loosen the terminal screws with a POZIDRIV® PZ1 screwdriver. Connect the electrical wires to the connector. 2 Tighten the terminal screws with a POZIDRIV® PZ1 screwdriver. 3 Tighten the cable gland. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 49 1 Put the cover on the housing 2 Turn the cover clockwise until it is fully engaged. 3 Attach the cover stop and lock screw. 4 Tighten the lock screw with a 3 mm Allen wrench. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 50: Electrical Installation: Output Options With An M12 Male Connector

    1 Power supply 2 Resistor for HART® communication (typically 250 ohms) 3 Optional connection to the grounding terminal 4 Output: 12...30 VDC for an output of 21.5 mA at the terminal 5 Device www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 51: Devices For Hazardous Locations

    • Close unused cable glands with dummy plugs 3. The diameter of the outer sheath of the electrical cable (for the power supply and current output) must be 6…10 mm or 0.24…0.39¨. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 52: Networks

    1 Address of the device (0 for point-to-point connection) 2 4...20 mA + HART® 3 Resistor for HART® communication (typically 250 ohms) 4 Power supply 5 HART® converter 6 HART® communication software www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 53: Multi-Drop Networks

    1 Address of the device (each device must have a different address in multidrop networks) 2 4 mA + HART® 3 Resistor for HART® communication (typically 250 ohms) 4 Power supply 5 HART® converter 6 HART® communication software www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 54: Start-Up

    • A connection to a system or PC with AMS™. You can download the Device Description (DD) file from the website. • A connection to a HART® Field Communicator. You can download the Device Description (DD) file from the website. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 55: Digital Display Screen

    C6.4.2 1st Value Variable (1st Meas. page) is set to "Level", then the device shows "Level" as the current output percentage in Normal mode (refer to item 1 in the illustration). www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 56: Keypad Buttons

    [Up] the status message page) Program mode: Program mode: Increase value or change parameter Program mode: Program mode: Keypad functions For more data on keypad functions, refer to on page 68. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 57 This will operate the device. How to operate the keypad buttons with a bar magnet Figure 5-4: How to operate the keypad buttons with a bar magnet Equipment needed • Bar magnet www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 58: Remote Communication With Pactware

    Refer also to the PACTware Consortium site at http://www.pactware.com. Figure 5-5: Screen from the PACTware™ user interface 1 DTM menu 2 Information for device identification 3 Installation parameters menu and menu items www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 59: Remote Communication With The Ams™ Device Manager

    • Store and read process data. • Store and read diagnostic status information. • Help plan preventive maintenance to reduce a plant's downtime to a minimum. You can download the DD file from our website. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 60: Operation

    2 One value and % bar graph of the scale for the measurement value 3 Two values 4 Two values and % bar graph of the scale for the top measurement value 5 Three values www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 61 Abbreviations of measurement types used in Normal mode Measurement type Abbreviation Distance Level Reflection Sensor value Volume Ullage volume Mass Ullage mass UllM Linearized distance Ldis or Distance Lin. Linearized level LLvl or Level Lin. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 62 [> > > > ]+[ ] [Escape] Change screen (measurement pages 1 and 2, and the status [Down] message page) Change screen (measurement pages 1 and 2 and the status [Up] message page) www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 63 (feet), custom length unit connection (flange face or thread stop) to the surface of the liquid. You cannot change this value in Program mode. Refer also to "Distance" in this table. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 64: Program Mode

    Quick Setup menu is mandatory. It is not possible to enter the D Service D Service D Service D Service menu. This menu is for factory calibration and approved personnel only. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 65: Protection Of The Device Settings (Access Levels)

    • Push 2 × [ ], [> > > > ], 5 × [ ], [> > > > ], [ ] and [> > > > ] to go to the menu C7.2 Security. • Push [> > > > ] to enter menu item C7.2.1 Login. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 66 If you de-energize the device and then energize it again, the access level will go back to "User". If you do not touch the keypad for 5 minutes, the device goes back to Normal mode and the access level will go back to "User". www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 67: How To Get Access To The Quick Setup Menu

    100. Push [^ ^ ^ ^ ] at the end of each step of the procedure to continue to the next step. • End of the procedure. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 68: Keypad Functions

    C2.2). • Scroll up the menu list (for example, from menu C2 to menu C1). • Scroll up the sub-menu list (for example, from sub-menu C2.2 to sub-menu C2.1). www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 69 If you push these buttons immediately after you change a parameter, the device also ignores this change and goes back to the menu. Down Scroll down the list Scroll up the list www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 70 If the cursor is on a number, this button increases the digit value. If the cursor is on the decimal point, this button moves the decimal point to the right (this increases the value by a factor of 10). www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 71: How To Save Settings Changed In Program Mode

    "Yes" or No", push [^ ^ ^ ^ ] to accept (Yes) or reject (No) the new settings. If you push [^ ^ ^ ^ ] when the screen is set to "Yes" or No", the display goes back to Normal mode. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 72: Menu Overview

    A4.2.1.10 Empty Spectrum Graph A4.2.1.11 Save Spectrum? A4.2.1.12 Empty Spectrum Enable 1 The device shows this menu item if you set the menu item A4.2.1.1 to "Partial, Average" or "Partial, Max" www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 73 1 You must enter the "Expert" password in A3 Login or C7.2.1 Login to find and use this menu 2 The device shows this menu item if you make a strapping table in menu C.3 Conversion www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 74 C4.1.2 0% Range C4.1.3 100% Range C4.1.4 Current Out. Range C4.1.5 Error Function C4.1.7 Low Error Current C4.1.8 High Error Current C4.1.9.2 Trimming / 4mA Trimming C4.1.9.5 Trimming / 20mA Trimming www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 75 C5.1.4.2 HART Variables / HART sec./CO2 Var. C5.1.4.3 HART Variables / Tertiary Var. C5.1.4.4 HART Variables / Quaternary Var. C6 Display C6 Display C6.1 Language C6 Display C6 Display C6.2 Backlight C6.3 Contrast www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 76 C7.2.1 Login C7.2.2 Change Password C7.2.3 Reset Passwords C7.2.4 Unlock Extended Range C7.2.5 Unlock SIL C7.3 Errors C7.3 Errors C7.3.1 Message View C7.3 Errors C7.3 Errors C7.3.2.1 Error-Mapping / Sensor: Information www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 77: Function Description

    If you do not enter "Function the password, you can only change description" settings for the "user" access level. Protection of For more data, refer to the device settings (access levels) page 65. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 78 110. Minimum access level to do the Minimum access level to do the Minimum access level to do the Minimum access level to do the procedure: procedure: Expert procedure: procedure: www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 79 Normal mode after 1 hour. Minimum access level to do the Minimum access level to do the Minimum access level to do the Minimum access level to do the procedure: procedure: procedure: procedure: Expert www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 80 Normal mode after 1 hour. Minimum access level to do the Minimum access level to do the Minimum access level to do the Minimum access level to do the procedure: procedure: procedure: procedure: Expert www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 81 Normal mode after 1 hour. Minimum access level to do the Minimum access level to do the Minimum access level to do the Minimum access level to do the procedure: procedure: procedure: procedure: Expert www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 82 C7.5 Units C7.5 Units. This menu item is only available if you set up a linearization table in menu item C3.1 Edit Table C3.1 Edit Table C3.1 Edit Table C3.1 Edit Table. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 83 1 The default value is the measured value at the time that you start the simulation www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 84 0.0...3.4449 ft Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: Expert setting: setting: www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 85 Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: Expert setting: setting: www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 86 Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: setting: setting: Expert www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 87 Minimum access level to do the procedure: 0.0 mm / 0.0¨ Minimum access level to do the procedure: Minimum access level to do the procedure: 0.0...100.0 kg / Expert 0.0...220.46 Linearization: 0.0...100.0 mm / ¨ 0.0...3.937 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 88 C4.1.8. Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: setting: setting: Expert www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 89 68 (values in menu items). Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: setting: setting: Operator www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 90 Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: Expert setting: setting: www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 91 "One Value & Bar" or "Two Values & Bar". Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: setting: setting: User www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 92 Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: setting: setting: User www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 93 Minimum access level to change the Minimum access level to change the Minimum access level to change the Minimum access level to change the setting: setting: User setting: setting: www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 94 "operator" and "expert" access levels. For password "Function the procedure to change the password, description" refer to Protection of the device settings (access levels) on page 65 (How to change the password). www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 95 C7.5.4.2 Offset Enter an offset value. 0.0 m³ — C7.5.4.3 Factor Enter a factor. Multiply the measured value by this factor to change m³ (cubic metres) to the custom volume unit. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 96 2 "Lin. Distance" and "Lin. Level" are available if you created a linearized value table in menu C3 Conversion. "Volume" and "Ullage Vol- ume" are available if you created a level-volume table in menu C3 Conversion. "Mass" and "Ullage Mass" are available if you created a level-mass table in menu C3 Conversion. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 97: Further Information On Device Configuration In Program Mode

    • [^ ^ ^ ^ ] to confirm. "Medium Slope". If the surface of the product has a large angle, select "Steep Slope". www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 98 Current Out. 1 Var. is set to "Distance", • [^ ^ ^ ^ ] to confirm. illustration 2 shows the position of 0% output as a distance below the flange facing or thread stop of the process connection. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 99 [^ ^ ^ ^ ] to confirm. to "No" to cancel the changes to the device settings and go back to Normal mode. Set to "Back" to stay in Program mode. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 100: Empty Spectrum Recording

    "Expert" access level. If it is the default 5 × [ ], [> > > > ] and 8 × [ ] password, enter "0058". • [^ ^ ^ ^ ] to confirm. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 101 "Yes", the device will keep this empty ("No" or "Yes"). spectrum recording. If you set the menu • [^ ^ ^ ^ ] to confirm. item to "No", the device will reject this data. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 102: Hart® Network Configuration

    • Enter the value 000 and push [^ ^ ^ ^ ] to confirm. • Push [^ ^ ^ ^ ] again and again to go back to the Save Configuration? Save Configuration? screen. Save Configuration? Save Configuration? www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 103: Distance Measurement

    If C4.1.1 Current Out. 1 Var. is set to "Distance" and C4.1.2 0% Range (standard scale) is set in the blocking distance, then the device will not be able to use the full current output range. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 104 C6.4.2 and C6.5.2 (1st Value Variable) and menu C1 Install. Parameters. If you change C1.10 Reference Offset, then we recommend that you change C6.4.3 / C6.5.3 (0% Range) and C6.4.4 / C6.5.4 (100% Range) by the same quantity. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 105: Level Measurement

    If C4.1.1 Current Out. 1 Var. is set to "Level" and C4.1.3 100% Range (standard scale) is set in the blocking distance, then the device will not be able to use the full current output range. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 106 C6.4.2 and C6.5.2 (1st Value Variable) and menu C1 Install. Parameters. If you change C1.11 Tank Bottom Offset, then we recommend that you change C6.4.3 / C6.5.3 (0% Range) and C6.4.4 / C6.5.4 (100% Range) by the same quantity. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 107: How To Configure The Device To Measure Volume Or Mass

    The device will give more accurate volume readings if you give more conversion data in these areas: • Surfaces with curves. • Sudden changes in the cross section. Refer also to the illustration that follows: www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 108 If you push [^ ^ ^ ^ ] when the screen is set to "Yes", the device will delete the data for the strapping table and go back to Normal mode. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 109: How To Measure Correctly In Silos With Curved Or Conical Bottoms

    Yes and push [^ ^ ^ ^ ]. The device will go back to Normal mode. For more data on menu items, refer to Function description on page 77 table C: Full Setup. – www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 110: How To Make A Filter To Remove Radar Signal Interference

    100. Push [^ ^ ^ ^ ] at the end of each step of the procedure to continue to the next step. For more data on empty spectrum scans, refer to Function description on page 77 table A. – Quick Setup menu (menu item A4.2). www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 111: Status Messages And Diagnostic Data

    If the device status changes, the device shows a status symbol in the top left corner of the display screen in Normal mode: Figure 6-11: Device status: Normal mode 1 Device status symbol (NAMUR NE 107) www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 112 1 Device status letter code (NAMUR NE 107). In this example, M = Maintenance required. 2 Description of error If the device shows an error message, refer to the table that follows for more data and to find a solution to a problem. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 113 Inconsistent Parameters Internal bus communication error. De-energize and then energize the device again. Sensor Comm. Error Internal bus communication error or hardware failure. If the message is shown again, tell the supplier. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 114 If the message is shown again, tell the supplier. C C C C Electronics Electronics Electronics Electronics FW Update A firmware update of the Wait for the firmware update to converter module continues. finish. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 115 Electronics Electronics Elec. Temp. Out Of Spec. The temperature of the converter Make sure that the device is is not in the specified limits. operated in the permitted ambient temperature range. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 116 Empty Spectrum invalid The empty spectrum recording Do a new empty spectrum does not agree with the process recording. conditions at this time (e.g. the tank height was changed). www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 117 Microwave Supply Voltage Error 1 DM = data manager 2 CO = current output 3 This error message is shown if the device is in SIL mode. CO = current output. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 118: Service

    O-rings are correctly greased or, if it is necessary, replaced. For more data Spare parts about the replacement of the O-rings, refer to on page 163. Figure 7-1: Maintenance of the O-rings 1 Display cover 2 Terminal compartment cover www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 119: How To Clean The Top Surface Of The Device

    Purge the antenna at intervals to make sure that the inner surface of the antenna stays clean and the device measures accurately. For more data, refer to the table that follows: www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 120: Service Warranty

    3 years after delivery of the last production run for the device. This regulation only applies to spare parts which are subject to wear and tear under normal operating conditions. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 121: Availability Of Services

    • such dangerous substances, • to enclose a certificate with the device confirming that it is safe to handle and stating the product used. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 122: Form (For Copying) To Accompany A Returned Device

    The user must dispose of the WEEE to a designated collection point for the recycling of WEEE or send them back to our local organisation or authorised representative. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 123: Technical Data

    4 Distance to product surface, where change in frequency is proportional to distance 5 Differential time delay, Δt 6 Differential frequency, Δf 7 Frequency transmitted 8 Frequency received 9 Frequency 10 Time www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 124 "DIRECT PLUS" MODES It is important to enter the correct dielectric constant value in menu item C2.2 Epsilon R Product. If this value is incorrect, the device will not measure level accurately. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 125: Technical Data

    Min. tank height 1 m / 40¨ Recommended minimum Antenna extension length + antenna length + 0.3 m / 12¨ blocking distance Min. distance for reflection 1 m / 3.3 ft measurement www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 126 -40…+100°C / -40…+212°F (the process connection temperature must agree with the temperature limits of the gasket material. Refer to "Materials" in this table.) Ex: see supplementary operating instructions or approval certificates www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 127 Cable gland Standard: none Options: Plastic (Non-Ex: black, Ex i-approved: blue); nickel-plated brass; stainless steel; M12 (4-pin connector) Weather protection (Option) Stainless steel (1.4404 / 316L) www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 128 Max. ±15 mm / 0.6¨ for the full temperature range Digital temperature drift Multi-drop operation Yes. Current output = 4 mA. Enter Program mode to change the polling address (1...63). Available drivers FC475, AMS, PDM, FDT/DTM www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 129 Minimum cycle time 250 ms Output data Level, distance, volume, ullage volume, mass, ullage mass Input data None Link Active Scheduler Supported NAMUR NE 107 data Supported with FF field diagnosis (FF-891) www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 130 EU: Electromagnetic Compatibility directive (EMC) Radio approvals EU: Radio Equipment directive (RED) FCC Rules FCC Rules FCC Rules FCC Rules: Part 15 Industry Canada Industry Canada: RSS-211 Industry Canada Industry Canada www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 131 4 T*°C = 100°C or 130°C. For more data, refer to the related Ex approval certificate. 5 T* = 100°C or 130°C. For more data, refer to the related Ex approval certificate. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 132: Measuring Accuracy

    1 Minimum recommended blocking distance = antenna extension length + antenna length + 11.81¨ To calculate the accuracy at a given distance from the antenna, refer to Technical data on page (measuring accuracy). www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 133: Minimum Power Supply Voltage

    Figure 8-5: Minimum power supply voltage for an output of 21.5 mA at the terminals (Hazardous Location approval (Ex d / XP/NI)) X: Power supply U [V DC] Y: Current output load R [Ω] www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 134: Guidelines For Maximum Operating Pressure

    2 Process connection temperature, T [°C] 3 Process pressure, p [psig] 4 Process connection temperature, T [°F] 5 Threaded connection, G (ISO 228-1) 6 Threaded connection, G (ISO 228-1). Flange connection, PN40. 7 Flange connection, PN16 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 135 2 Process connection temperature, T [°C] 3 Process pressure, p [psig] 4 Process connection temperature, T [°F] 5 Threaded connection, NPT (ASME B1.20.1). Flange connection, Class 300. 6 Flange connection, Class 150 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 136: Dimensions And Weights

    12 mm or 0.28 0.47 • … … ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 137 DN200/8¨ 5.94 7.28 26.06 33.35 7.48 1 This is the dimension without the antenna extension option. A maximum of 10 antenna extensions are available. Each antenna exten- sion is 4.1¨ long. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 138 12 mm or 0.28 0.47 • … … ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 139 1 These are the minimum and maximum values without the antenna extension option. A maximum of 10 antenna extensions are avail- able. Each antenna extension is 4.1¨ long. 2 If the device has the 2° slanted flange option. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 140 12 mm or 0.28 0.47 • … … ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 141 8.46 9.72 25.87 33.35 35.63 7.48 1 This is the dimension without the antenna extension option. A maximum of 10 antenna extensions are available. Each antenna exten- sion is 4.1¨ long. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 142 12 mm or 0.28 0.47 • … … ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 143 DN150/6¨ PTFE 5.94 7.28 8.70 15.98 5.67 1 This is the dimension without the antenna extension option. A maximum of 5 antenna extensions are available. Each antenna extension is 4.1¨ long. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 144 12 mm or 0.28 0.47 • … … ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 145 2 If the device has the PP or PTFE flange protection option, then f = 0.79¨. If the device has the 2° slanted flange option, then f = 0.39¨. 3 If the device has the 2° slanted flange option, then g = 2° www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 146 12 mm or 0.28 0.47 … … ¨ Cable glands for cQPSus-approved devices must be supplied by the customer. • A weather protection cover is available as an accessory with all devices. • www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 147 This option is available for all Metallic Horn antennas. Flange connections must have a pressure rating of PN16 (EN 1092-1), PN40 (EN 1092-1), Class 150 (ASME B16.5), Class 300 (ASME B16.5), or must be a low-pressure flange (PN01 / 15 psig). www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 148 2 Left side (with weather protection closed) 3 Rear view (with weather protection closed) Weather protection: Dimensions and weights Dimensions Weights [kg] [mm] [inch] [mm] [inch] [mm] [inch] [kg] [lb] www.hawkmeasurement.com Weather 6.97 6.02 8.50 protection www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 149 Flange plate option, DN150 PTFE Drop antenna +0.7 +1.54 1 Standard length = without antenna extensions 2 This option is for Metallic Horn and Drop antennas 3 This option is for Metallic Horn antennas www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 150: Description Of Hart Interface

    An FSK or HART® modem is included in field devices and manual control units. It is necessary to have an external modem for PC-supported workstations. The external modem is connected to the serial or USB interface. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 151: Software History

    9.3.1 Point-to-Point connection – analogue / digital mode Point-to-Point connection between the signal converter and the HART® Master. The current output of the device is passive. Point-to-point connection Also refer to on page 52. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 152: Multi-Drop Connection (2-Wire Connection)

    • System card that includes the "Easy Upgrade Option" • Field Communicator Easy Upgrade Programming Utility • HART® Device Description file For more data, refer to the Field Communicator User’s Manual. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 153: Operation

    AMS and operating using the local keyboard. The service menu parameters are not supported and simulation is only possible for current outputs. The online help for each parameter contains its function number as a reference to the local device display. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 154: Field Device Tool / Device Type Manager (Fdt / Dtm)

    Configure / Setup Quick Setup General Security Units Application Full Setup Process Output Display Device Hart Calibration Service Information Device Diagnostics Device Status Actual Values Simulation Test/Reset Information Process Variables Measured Values Inputs/Outputs www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 155: Ams Menu Tree (Details For Settings)

    Function / 1st Value Variable / Page Format 1st Value / 2nd Value Variable / Format 2nd Value / 3rd Value Variable Format 3rd Value / 0% Range / 100% Range www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 156 Service Calibration Calibration Current Output 1 Sensor Manual Correction Offset / Manual Correction Factor / Correction Offset / Correction Factor Rd, Opt Correction Offset Extended Rd, Opt Correction Factor Extended www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 157 / Mass / Distance Linearization Opt, Rd Opt, Rd / Ullage / Ullage Mass Inputs / Out / PV % Range / PV output current / SV / TV / QV www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 158: Appendix

    Make a selection from each column to get the full order code. S24S 4 D Senator S24S Radar - 24 GHz radar (FMCW) level transmitter for solids from granulates to rocks (up to Senator S24S Radar - 24 GHz radar (FMCW) level transmitter for solids from granulates to rocks (up to...
  • Page 159 Order code (complete this code on the pages that follow) S24S S24S Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 160 Order code (complete this code on the pages Order code (complete this code on the pages Order code (complete this code on the pages that follow) that follow) that follow) that follow) www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 161 Order code (complete this code on the pages S24S S24S Order code (complete this code on the pages Order code (complete this code on the pages that follow) that follow) that follow) that follow) www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 162 4 LPR = You can install the antenna in a closed tank or outdoors, but the antenna must point down. Do not install LPR devices near sen- sitive installations (e.g. a radio astronomy station). TLPR = You must install the antenna in a closed tank. 5 Only for Metallic Horn antennas www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 163: Spare Parts

    XFDX090400 525 mm / 21¨ XFDX090500 630 mm / 25¨ XFDX090600 735 mm / 29¨ XFDX090700 840 mm / 33¨ XFDX090800 945 mm / 37¨ XFDX090900 1050 mm / 41¨ XFDX091000 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 164 Stainless steel blind cover (11) + gasket (8) (8) + cover stop (1) XFDX01020D Aluminium display cover(9) (9) + gasket (8) XFDX01030D Stainless steel display cover (9) (9) + gasket (8) XFDX01040D www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 165 Cable entry / ½ NPT stainless steel non-Ex (GP) / Ex i (5) XFDX051000 Cable entry / ½ NPT stainless steel Ex d (5) XFDX051100 Cable entry / ½ NPT stainless steel cQPSus (5) XFDX051200 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 166: Accessories: General Items

    Weather protection XFDX060100 Viator RS232 / HART converter XFDX060200 Viator USB / HART converter XFDX060300 Display extractor, magnet and cover wrench XFDX060400 — USB / 24 V DC power supply XFDX060500 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 167: Accessories: Process Connection Kits

    Disc with holes, drilled according to DN100 PN2.5...PN40 / 4¨ 150 lb XF70000N17 Disc with holes, drilled according to DN150 PN2.5...PN40 / 6¨ 150 lb XF70000N18 Disc with holes, drilled according to DN200 PN2.5...PN40 / 8¨ 150 lb XF70000N19 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 168 Disc with holes, drilled according to DN100 PN2.5...PN40 / 4¨ 150 lb XF70000062 Disc with holes, drilled according to DN150 PN2.5...PN40 / 6¨ 150 lb XF70000063 Disc with holes, drilled according to DN200 PN2.5...PN40 / 8¨ 150 lb XF70000064 www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 169 1 Make sure that the slanted flange is made of the same material as the Drop antenna 2 For more data, refer to the "Technical data: Dimensions and weights" section in this document www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 170: Glossary

    Level Height from the bottom of the silo (user-defined) to the surface of the top Level Level product (Tank height – distance). See the diagrams at the end of this section. www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 171 Ullage volume Ullage volume Unfilled volume. See the diagrams at the end of this section. Ullage volume Ullage volume Volume Volume Total volume of silo contents. Volume Volume www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 172 Figure 10-4: Measurement definitions: distance 1 Distance 2 Blocking distance 3 Flange facing 4 Gas (Air) 5 Tank height 6 Ullage volume or mass Figure 10-5: Measurement definitions: level 1 Level 2 Volume or mass www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 173: Notes

    NOTES Senator S24S www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 174 NOTES Senator S24S www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 175 NOTES Senator S24S www.hawkmeasurement.com 01/2019 - Senator S24S Radar Manual v1.00 en...
  • Page 176 Hawk Measurement Systems (Head Office) 15 - 17 Maurice Court, Nunawading VIC 3131, AUSTRALIA Phone: +61 3 9873 4750 Fax: +61 3 9873 4538 info@hawk.com.au Hawk Measurement 5010 Gateway Drive, Medina, OH 44256, USA Phone: +1-888-429-5538 Phone: +1 978 304 3000 Fax: +1 978 304 1462 info@hawkmeasurement.com...

Table of Contents