King Canada 8201NL Instruction Manual page 6

18 ga. x 2” brad nailer
Table of Contents

Advertisement

Sequential Mode
In sequential mode, the nailer is actuated by depressing the nailer nose against the work surface, the trigger then needs to be pulled and
released each time a nail is driven.
FIRING MODE &
VERIFICATION
OPERATING A CONTACT SAFETY TRIP NAILER (SEQUENTIAL MODE):
• The operator is required to have the finger off the trigger and the nose of the nailer to be placed on the
workpiece.
• The contact safety trip mechanism is then depressed against the workpiece and the trigger is pulled to
drive the nail.
• The trigger is released after each nail is driven.
• Move the nailer to the next location and repeat the above procedure.
VERIFICATION
• Disconnect the air supply from the air inlet.
• Empty all nails from the magazine.
• Make sure the trigger and the contact safety trip mechanism (nose) moves up and down without sticking.
• Connect the air supply to the nailer air inlet.
• Depress the contact safety trip mechanism against the workpiece without pulling the trigger. The nailer
must not cycle. Never use the tool if a cycle occurs.
• Hold the nailer clear of the workpiece. The contact safety trip mechanism should return to its original
down position. Pull the trigger. The tool must not cycle. Never use the nailer if a cycle occurs.
• Depress the contact safety trip mechanism against the workpiece and pull the trigger, the nailer must
cycle.