LG GR-L814FBI Owner's Manual page 34

Built-in sxs refrigerator
Table of Contents

Advertisement

Problem
Icemaker is not
Demand exceeds ice storage
making enough
capacity.
ice.
House water supply is not
connected, valve is not turned on
fully, or valve is clogged.
Water filter has been exhausted.
Low house water supply pressure.
Reverse Osmosis filtration system is
used.
Tubing connecting refrigerator to
house supply valve is kinked.
34
Possible Causes
Care and maintenance
Solutions
The icemaker can produce approximately
70 ~ 100 cubes in a 24 hour period.
Connect the refrigerator to a cold water
supply with adequate pressure and turn
the water shutoff valve fully open.
If the problem persists, it may be
necessary to contact a plumber.
It is recommended that you replace the
water filter:
• Approximately every six months.
• When the water filter indicator turns on.
• When the water dispenser output
decreases.
• When the ice cubes are smaller than
normal.
The water pressure must be between 140
kPa and 500 kPa on models without a
water filter and between 280 kPa and 500
kPa on models with a water filter.
If the problem persists, it may be
necessary to contact a plumber.
Reverse osmosis filtration systems can
reduce the water pressure below the
minimum amount and result in icemaker
issues. (Refer to Water Pressure section.)
The tubing can kink when the refrigerator
is moved during installation or cleaning
resulting in reduced water flow. Straighten
or repair the water supply line and arrange
it to prevent future kinks.