Velleman DVM902 User Manual page 9

Cat ii 700 v / cat iv 600 v
Hide thumbs Also See for DVM902:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
auto power-off ..................................................................... yes
dimensions ................................................... 190 x 100 x 40 mm
weight (with battery) ......................................................... 320 g
storage environment
temperature ................................................. -20 °C to 60 °C
humidity ............................................................ < 90 % RH
test lead probe .......... CAT II 700 V / CAT IV 600 V, 15 A; L = 90 cm
IP rating ........................................................................... IP20
9.1 DC VOLTAGE
range
600 mV
6 V
60 V
600 V
700 V
Overload protection: 700 V DC or AC rms
Impedance: 10 MΩ
9.2 AC VOLTAGE
range
6 V
60 V
600 V
700 V
AC true RMS
Frequency range: 40 Hz-2 kHz
Overload protection: 700 V DC or AC rms
Impedance: 10 MΩ
V. 01 – 05/11/2019
DVM902
Do not measure circuits that may contain voltages
> 700 VDC or > 700 VAC
resolution
0.1 mV
1 mV
10 mV
100 mV
1 V
Do not measure circuits that may contain voltages
> 700 VDC or > 700 VAC
resolution
1 mV
10 mV
100 mV
1 V
accuracy
± (0.5 % + 2)
± (0.8 % + 2)
accuracy
± (0.8 % + 3)
± (1.2 % + 3)
9
©Velleman nv

Advertisement

Table of Contents
loading

Table of Contents