Troubleshooting - Dyna-Glo DGB300CNP Manual

2-burner lp gas grill
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

If you have any questions regarding the product, please call customer service at 1-877-447-4768,
8:30 a.m. – 4:30 p.m., CST, Monday – Friday.
PROBLEM
The burner will not
light using the
ignitor procedure
(weak or no spark
being generated).
Low Heat.
Excessive
Flare Ups.
POSSIBLE CAUSE
1. The igniter electrode may be
covered with grease or residue.
2. The igniter electrode may
have a loose or disconnected
wire.
3. Cracked or broken ignition
electrode.
1. Insufficient gas pressure to
the unit.
1. Grease and/or residue
build-up on heat tents or in
firebox.
2. Excessive dripping of fat or
marinade from food.
3. Cooking temperature too high.
CORRECTIVE ACTION
1. Clean the ignitor electrode.
2. Check the connection and reconnect any
loose or disconnected wires.
3. Replace ignition electrode (see Replace-
ment Parts List).
1. Call a qualified service agency to check
the gas supply pressure and correct the
pressure.
1. Clean the grill components.
2. Trim the fat from meat and use non-oil
based marinades.
3. Lower temperature accordingly.
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dgb300cnp-d

Table of Contents