Defrost
The models below have automatic or frost free design and do not require manual defrosting under normal
conditions.
Base Model
1224
1215/1224/2218/2245/
2224/2260
1215/1224/2218/2245/
2224/2260
CO29
CO1224
1224FZR
1224FZR
The defrost settings for 3000 series models are determined by zone.
Zones
Beverage/Drinks
Market/Fresh
Root/Root Cellar
Pantry
White Wine
Red Wine
Sparkling Wine
Polar
Deli
Remove Fan and Cover
CONVECTION COOLING
This unit is equipped with an advanced convection
cooling system. Convection cooling stabilizes cabinet
temperature, cools product faster and increases
energy efficiency.
Evaporator Fan
The evaporator fan is responsible for circulating warm
air from the refrigeration zone, past the evaporator
and back into the refrigerated zone.
Defrost Settings
Variant(s)
Compressor Run Time
Between Defrost (Hours)
RF
WC, ZWC
R, RSOD, RDC,
BEV, DC, DWR,
RGL
F
F
Freezer Mode
Refrigerator Mode
Defrost Settings by Zone (3000 Series)
Compressor Run Time
Between Defrost (Hours)
12
12
12
12
12
12
12
6
12
Duration in Minutes
12
12
12
12
12
6
12
Duration in Minutes
Duration in Minutes
(Minimum)
5
5
5
5
5
5
5
5
5
The evaporator fan is factory set to have a 1 minute
delay at the beginning of a cooling cycle. This delay
gives the evaporator time to cool properly before
warm air is passed over it. The fan will continue to run
for an additional 2 minutes at the end of a cooling
cycle. Fan delay times can be modified through the
service menu.
Evaporator fan operation is also determined by door
switch state. If the door switch circuit opens, the fan
will stop. When the door switch circuit is closed the
fan will either continue running with the cooling cycle,
Stop Temperature
(Maximum)
°F (°C)
45
15 (-9)
45
45 (7)
45
42 (6)
18
18
45 (7)
45
42(6)
45
42(6)
Stop Temperature
(Maximum)
°F (°C)
60
42 (6)
60
42 (6)
60
45 (7)
60
42 (6)
60
45 (7)
60
45 (7)
60
45 (7)
20
42 (6)
60
42 (6)
u-line.com
Thermistor 2
n/a
Defrost 1