USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Anti-Tip Bracket
CAUTION
The anti-tip bracket must be installed to prevent
the unit from tipping when doors are fully
opened or excess weight is placed on the front
of the unit.
The anti-tip bracket has multiple mounting options.
Mounting will depend on your particular cabinet
configuration. Locate 3 #8x5/8" screws included with
your unit.
TOP MOUNT
For ease of installation, the anti-tip bracket is pre-
installed in the top mount position.
1. Completely slide the unit into its position in the
cabinet. Be certain unit height is properly adjusted.
(See GENERAL INSTALLATION).
2. Open door completely. Make certain door clears
surrounding cabinetry.
3. Using a 3/32" (2.50 mm) drill bit, drill 3 pilot holes
5/8" (16 mm) deep into bottom of counter top. Use
the anti-tip bracket as a template.
4. Install 3 #8x5/8" screws into the plate using a #2
Phillips head screwdriver.
SIDE MOUNT
Side-by-Side Installation 1
Side mount position is used when you are unable to
mount
the
bracket
to
countertop.
1. Remove the pre-installed anti-tip bracket from the
top mount position and align the bracket to the
hinge side of the unit as shown above.
2. Reinstall the 2 #8x5/8" screws into the plate using
a #2 Phillips head screwdriver.
3. Completely slide the unit into its position in the
cabinet. Be certain unit height is properly adjusted.
(See GENERAL INSTALLATION).
4. Open door completely. Make certain door clears
surrounding cabinetry.
5. Using a 3/32" (2.50 mm) drill bit, drill 3 pilot holes
5/8" (16 mm) deep into cabinetry frame using the
anti-tip bracket as a template.
6. Install 3 #8x5/8" screws into the plate using a #2
Phillips head screwdriver.
u-line.com