Operation Limits; Precautions For Selecting The Location - Daikin RXP50K3V1B Installation Manual

Table of Contents

Advertisement

Operation limits

Use the system in the following temperature and humidity ranges for safe and effective operation.
Outdoor temperature
Indoor temperature
Indoor humidity
(a)
To avoid condensation and water dripping out of the unit. If the temperature or the humidity is beyond these conditions, safety
devices may be put in action and the air conditioner may not operate.
The setting temperature range of the remote controller is:
Cooling operation
18-32°C

Precautions for Selecting the Location

1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the neighbors of
the user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
7) Install units, power cords and inter-unit wire at least 3m away from television and radio sets. This is to prevent interference to
images and sounds. (Noises may be heard even if they are more than 3m away depending on radio wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.
NOTE
Cannot be installed hanging from ceiling or stacked.
CAUTION
When operating the air conditioner in a low outdoor ambient
temperature, be sure to follow the instructions described below.
• To prevent exposure to wind, install the outdoor unit with its suction
side facing the wall.
• Never install the outdoor unit at a site where the suction side may be
exposed directly to wind.
• To prevent exposure to wind, it is recommended to install a baffle
plate on the air discharge side of the outdoor unit.
• In heavy snowfall areas, select an installation site where the snow
will not affect the unit.
3
Cooling
–10~46°C
18~32°C
(a)
≤80%
Heating operation
10-30°C
Heating
–15~24°C
10~30°C
AUTO operation
18-30°C
● Construct a large canopy
● Construct a pedestal
Install the unit high enough off the
ground to prevent burying in snow.
English

Advertisement

Table of Contents
loading

Table of Contents