Amana AGR5330BAS Installation Instructions Manual page 15

30" (76.2 cm) freestanding gas ranges
Table of Contents

Advertisement

To Convert Gas Pressure Regulator
1. Open broiler door and remove broiler rack. The gas pressure
regulator is located in the back right-hand corner of the
broiler compartment.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
2. Remove the cap from the gas pressure regulator using
a flat-blade screwdriver.
NOTE: Make sure sealing washer remains in the same
position.
3. To convert to Natural gas, unscrew the plastic adjustment
screw by hand, turn it over, and screw it in again.
Inlet pressure
to LP gas
180º
A. Cap
B. Sealing washer
C. Adjustment screw
4. Reinstall the cap.
A
A. Cap
Inlet pressure
to Natural gas
A
B
C
To Convert Surface Burners
1. Remove burner grate, burner caps, and burners.
A
B
A. Burner cap
B. Burner
2. Locate LP gas orifice spuds for top burners in the bag
containing literature included with the range. Two Natural gas
spuds are stamped "149", one is stamped "110," and one is
stamped "165."
3. Remove the LP gas orifice spuds using a 7 mm combination
wrench.
4. Install the Natural gas orifice spuds using a 7 mm
combination wrench.
A. Spud
B. Holder
A
B
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agr5330bawAgr5330bab

Table of Contents