Amana AGR5330BAS Installation Instructions Manual page 13

30" (76.2 cm) freestanding gas ranges
Table of Contents

Advertisement

To Convert Gas Pressure Regulator
1. Open broiler door and remove broiler rack. The gas pressure
regulator is located in the back right-hand corner of the
broiler compartment.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
2. Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
NOTE: Be sure sealing washer remains in the same position.
3. To convert to LP gas, unscrew the plastic adjustment screw
by hand, turn it over, and screw it in again.
Inlet pressure
to Natural gas
A
B
C
A. Cap
B. Sealing washer
C. Adjustment screw
4. Reinstall the cap.
A
A. Cap
Inlet pressure
to LP gas
180º
To Convert Surface Burners
1. Remove burner grate, burner caps, and burners.
A
B
A. Burner cap
B. Burner
2. Locate LP gas orifice spuds for top burners in the bag
containing literature included with the range. Two LP gas
spuds are stamped "88", one is stamped with "70," and one
is stamped "96."
3. Remove Natural gas orifice spuds using a 7 mm combination
wrench.
4. Install LP gas orifice spuds using a 7 mm combination
wrench.
A. Spud
B. Holder
A
B
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agr5330bawAgr5330bab

Table of Contents