Installation; Space Requirements; Installation Process - Mitsubishi Electric E1032 Installation Manual

Hide thumbs Also See for E1032:
Table of Contents

Advertisement

2

Installation

2.1

Space Requirements

Installation plate thickness: 1.5 - 7.5 mm (0.06 - 0.3 inch)
Space requirements when installing the operator panel:
187 mm
(7.36 inch)
50 mm
(2.0 inch)
Caution:
The openings on the enclosure are for air convection. Do not cover these openings.
2.2

Installation Process

1. Unpack and check the delivery. If damage is found, notify the supplier.
Note:
Place the operator panel on a stable surface during installation.
Dropping it or letting it fall may cause damage.
Mitsubishi Electric, MA00816D
100 mm
(4.0 inch)
50 mm
(2.0 inch)
100 mm
(4.0 inch)
202 mm
(7.95 inch)
Panel cut out 166 x 149 mm
(6.54 x 5.87 inch)
x 7
Installation
100 mm
(4.0 inch)
57 mm
(2.24 inch)
7