Download Print this page

Instal Ation Procedure - Lefroy Brooks CB-4075 Installation, Operating, & Maintenance Instructions

Black archipelago thermostatic valve trim only

Advertisement

Installation Procedure
Lefroy Brooks always recommends that plumbing products be installed by a licensed professional.
Shut off main water supply before installation.
Note: Plaster guard
Keep a distance of 7mm at
least from the wall surface to
the front of the plaster guard
so that the trim kit CW-4075,
CB-4075 can be fitted
successfully.
wall surface
1
Position valve into the wall as the figure instructed.
2
Connect Water Supply Piping.
3
Cut a hole on the wall surface for fitting the trim kit. The hole dimension is as shown in figure 3.
4
Throw away the protective caps only when the building construction is completed and you are
ready to fit the trim kit. Take out the stopper.
87mm-112mm
Hot supply
1
Ø145mm-Ø150mm
3
Steps 1-4
Outlet
Cold supply
2
4
4