Sierra Flame STANFORD STANFORD-55G-NG-DELUXE Installation And Operating Instructions Manual

Sierra Flame STANFORD STANFORD-55G-NG-DELUXE Installation And Operating Instructions Manual

55l direct vent linear 36,000 btu

Advertisement

Quick Links

STANFORD 55L DIRECT VENT LINEAR
36,000 BTU
Natural Gas & Propane
Installation and Operating Instructions
MODEL:
STANFORD-55G-NG-DELUXE
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance
Do not touch any electrical switch; do not use any phone in your building
Immediately call your gas supplier from a neighbour's phone. Follow gas supplier's
instructions
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or gas
supplier.
WARNING: Improper installation, adjustment, alteration, services or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
PLEASE READ THIS MANUAL BEFORE
INSTALLING OR USING THIS APPLIANCE.
SAVE THIS MANUAL FOR FUTURE
REFERENCE.
CLIENT # LC773211
WARNING
any other appliance.
Page 1 of 58

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STANFORD STANFORD-55G-NG-DELUXE and is the answer not in the manual?

Questions and answers

Summary of Contents for Sierra Flame STANFORD STANFORD-55G-NG-DELUXE

  • Page 1 STANFORD 55L DIRECT VENT LINEAR 36,000 BTU Natural Gas & Propane Installation and Operating Instructions MODEL: STANFORD-55G-NG-DELUXE CLIENT # LC773211 WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 STANFORD 55L DESIGNER ELITE VISAGE CLEAN 36,000 BTU GAZ NATUREL ET PROPANE Manuel D’installation et Guide de l’utilisateur MODEL: STANFORD-55G-NG-DELUXE CLIENT # LC773211 AVERTISSEMENT ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉES DANS CETTE NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU D'EXPLOSION OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.
  • Page 3: Table Of Contents

    Table of Contents IMPORTANT SAFETY INFORMATION …………………………………………………………….. 4 – 5 INTRODUCTION ........................Specifications, Appliance Dimensions & Installation Codes ......... 6 - 7 Features, Remote Control Functions ..............8 - 10 Intended Use ......................11 General Safety ....................11 - 12 OPERATION ...........................
  • Page 4 • Read this owner’s manual carefully and completely before trying to assemble, operate or service this fireplace. Follow instructions for proper installation • Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 5 WARNING AVERTISSEMENT Do not use this appliance if any part has Ne pas utiliser cet appareil s’il a été plongé, been under water. Immediately call a meme partiellement, dans l’eau. Appeler un qualified service technician to inspect the technician qualifié pour inspecter l’appareil et appliance and to replace any part of the remplacer toute partie du système de control system and any gas control which...
  • Page 6: Introduction

    largeur et la profondeur de la cheminée. 1.0 INTRODUCTION 1.1 SPECIFICATIONS TABLE 1 ITEM NATURAL GAS (NG) PROPANE (LP) MAXIMUM INPUT: Hi 36,000 Btu/hr (10.55 kW) 32,000 Btu/hr (9.38 kW) MINIMUM INPUT: Lo 21,250 Btu/hr (6.23 kW) 26,000 Btu/hr (7.62 kW) MANIFOLD PRESSURE: 3.5”...
  • Page 7 APPLIANCE DIMENSIONS Figure 1 INSTALLATION CODES This appliance is a Direct Vent appliance which draws all combustion air from outside the building through an intake vent pipe. Installation must conform to local codes. In the absence of local codes, installation must conform to the National Fuel Gas Code ANSI Z223.1/NFPA 54, or the current Natural Gas and Propane Installation Code CSA B149.1.
  • Page 8 1.2 FEATURES Ignition system: Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter. Fan control * Optional * Variable speed control: For units equipped with a fan control, the knob controls the fan speed, turning the knob counter-clockwise turns it to the “Off”...
  • Page 9 Program Mode The Program function is controlled by the PROG/TIME button. The control may be programmed for up to two settings for weekdays and two settings for weekends. The control is preset to factory settings. When the Program Mode is activated, the unit will automatically be operating in the Thermostat Mode. The unit will turn on or off based upon room and set temperature.
  • Page 10 Fan Control The unit must be ON to operate the Fan. The Fan will turn on after 5 minutes of operation. Once the Fan comes on, it can be controlled using the FAN button. Press the FAN button, and the fan icon and speed will appear on the LCD screen. Press the UP or DOWN button to control the fan speed (0-6).
  • Page 11: Intended Use

    1.3 INTENDED USE / USAGE PROPOSÉ This appliance is intended to be used as a zero clearance fireplace. Cet appareil est destiné à être utilisé comme un foyer à dégagement zéro. 1.4 GENERAL SAFETY / SÉCURITÉ GÉNÉRALE • Maintain adequate clearances around air openings into the combustion chamber. •...
  • Page 12 IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. It is not unusual for gas fireplaces to give off some odors the first time they are burned. This is due to the oils and sealants in the manufacturing process.
  • Page 13: Operation

    2.0 OPERATION LIGHTING INSTRUCTIONS - for Intermittent Pilot FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. BEFORE LIGHTING smell all around the appliance area for gas.
  • Page 14 INSTRUCTIONS D'ALLUMAGE - Pilote intermittent POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT: Quiconque ne respecte pas à la letter les instructions dans la présente notice risqué de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. Cet appareil est équipé...
  • Page 15: Installation

    3.0 INSTALLATION 3.1 INSTALLATION & SAFETY NOTES / NOTES D'INSTALLATION ET DE SECURITE Read all instructions before starting installation and follow them carefully during installation to ensure maximum benefit and safety. Failure to follow these instructions will void your warranty and may present a fire hazard.
  • Page 16 3.3.1 MINIMUM CLEARANCES / DÉGAGEMENTS NON-COMBUSTIBLE BOARD – 12" (305mm) x 54.25" (1378mm) WILL BE SUPPLIED BY MANUFACTURER AND MUST BE ATTACHED TO TOP OF FIREPLACE SEE DIAGRAM PAGE 18 MINIMUM CLEARANCES TO COMBUSTIBLES A = 58” TO INTERNAL CEILING B = 2”...
  • Page 17 Clearances are in accordance with local installation codes and the requirements of the gas supplier. **The mantel placement chart on this page illustrates the allowable mantel sizes and placements. The 45 degree angle can be used to determine the allowable mantel size based on the elevation above the units upper trim.
  • Page 18 NON-COMBUSTIBLE BOARD 12 X 54.25 SUPPLIED BY MANUFACTURER 39.00 TO BOTTOM 40.00 TO TOP OF NON- COMBUSTIBLE STUD ON BOARD FROM EDGE BOTTOM OF FIREPLACE STUD The closest combustible material above the fireplace must be a minimum of 40.00” from the floor with the stud laying on edge as shown above.
  • Page 19: Gas Line Installation

    3.3.2 GAS LINE INSTALLATION / INSTALLATION DE LA LIGNE de GAZ  Install supply line using any piping approved for your installation meeting CAN/CGA 6.10, AA 3, ANSI Z21.24 or Z21.45. A qualified gas fitter should install the gas line in accordance with all local building codes. If codes permit, coiled copper tubing may be used for gas supply.
  • Page 20: Direct Vent Information

    3.3.3 DIRECT VENT INFORMATION / DIRECT VENT D'INFORMATION The unit must be connected to listed 2-ply aluminium venting, 4” flex vent on the exhaust side and listed 7” flex vent on the air intake side or can be used with Security Venting, Dura-Vent 4” x 6-5/8” with the use of Dura-Vent adapters part #’s 0924N3 &...
  • Page 21 Figure 6 Dura-Vent or Selkirk Direct-Temp Venting The minimum vent system for horizontal termination must consist of: Dura-Vent adapter Part # 0924N3 directly on top of unit 15” (305mm) vertical length of vent 90 degree elbow 15" (305 mm) length horizontally Wall thimble part #IMC1082A Dura-Vent Horizontal termination cap 0984/ or / Selkirk Horizontal termination cap 4DT-HC The maximum horizontal vent system consists of:...
  • Page 22 Security Venting The minimum vent system for horizontal termination must consist of: Dura-Vent adapter Part # 0924N3 directly on top of unit 15” (305mm) vertical length of vent 90 degree elbow 15" (305 mm) horizontal length of vent Wall thimble part #IMC1082A Horizontal termination cap SV4CHC The maximum horizontal vent system consists of: Dura-Vent adapter Part # 0924N3 directly on top of unit...
  • Page 23 2-Ply Aluminum Flex Vent The minimum vent system for horizontal termination must consist of: 15” (305 mm) vertical length (measured to center of vent pipe) with a 90 degree bend and a 15” (305 mm) horizontal length (measured from center of vent pipe) Wall thimble part# IMC1082A Horizontal termination cap part # IMC1070A or IMC1070B The maximum horizontal vent system consists of:...
  • Page 24 VERTICAL VENT TABLE NOTE: All vent dimensions are measured from the (All values are in feet) appliance surface where the vent connects to the point where exhaust gases exit the termination. REMARQUE: Toutes les dimensions sont mesurées à partir d'aération de la surface de l'appareil où l'évent se connecte au point où...
  • Page 25 34’ 20’ 15” MINIMUM 15” MAXIMUM (Example: Where A---A = Vertical @ 2 ½’ B---B = Horizontal @ 5’) Page 25 of 58...
  • Page 26 USE OF SEALANT Sealant is required on vent system joints, except Metal-Fab Sure-Seal direct vent system joints (figure 7). On longer vent runs, especially vertical runs, sealant will ensure that the combustion air enters from outdoors, and not through the vent joints. Use high temperature sealant, available from local suppliers, on the inner pipe joint, applying the sealant around the outside of the male part of the vent.
  • Page 27 Typical Dura- Vent, Security Chimney & Metal-Fab Venting Installation: Vent terminals shall not be recessed into a wall or siding. Fireplace Horizontal Wall Vent Terminations The position of the horizontal vent termination must be positioned in such a way as to meet all local building codes.
  • Page 28 Install the wall thimble, on the inside of the exterior wall, shield using wood screws. Attach the venting to the termination using sheet metal screws, for Z-Flex installations an Sierra Flame’s termination part # IMC1070A or IMC1070B shall be used and when using Simpson Dura-Vent or Security Venting a Simpson Dura-Vent termination part # P574 shall be used.
  • Page 29 TOUJOURS vérifier les codes locaux avant l'installation VENTILATION. ETC DÉGAGEMENTS, peut varier d'ÉTAT (PROVINCE). CONSULT DURAVENT PARTS LIST OR SIERRA FLAME’S FIREPLACE MANUFACTURING PARTS LIST FOR PART NUMBERS. CONSULTER LA LISTE DES PIÈCES DES FOYER DURAVENT OU LA LISTE DES PIÈCES SIERRA FLAME de fabrication POUR LA LISTE DES PIÈCES DE RÉFÉRENCE.
  • Page 30 Termination above Roof Consult local codes for minimum vent cap height above the roof (X), vent must be a minimum of 2’ from any wall. To prevent water seepage; install the flashing with upper portion under the roofing material and the lower portion over the roofing material.
  • Page 31 In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code In accordance with the current ANSI Z223.1 / NFPA 54, National Fuel Gas Code † A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings ‡...
  • Page 32 3.3.4 GLASS INSTALLATION / INSTALLATION DE VERRE Burn medium positions are critical to the safe and clean operation of this appliance. Never add any other material into the firebox. Use only with burn medium supplied with this unit. Positions Burn moyennes sont critiques pour le fonctionnement sûr et propre de cet appareil.
  • Page 33 Page 33 of 58...
  • Page 34: Door Installation

    3.3.5 DOOR INSTALLATION / INSTALLATION DE LA PORTE Place the bottom of the door into the Bottom Door Channel / Placez le bas de la porte dans la Manche de bas de porte DOOR LOCK BRACKETS Insert your index fingers into gap at top of door and behind tabs on door lock bracket. Pull bracket towards you and over the lock to clip down into place.
  • Page 35: Initial Firing

    When closed properly the door latch will hook over the top of the door bracket and seal the door onto the fireplace. / Quand il est fermé correctement le loquet se brancher sur le dessus du support de porte et sceller la porte sur la cheminée. Removal is in reverse order.
  • Page 36: Pilot Flame Adjustment

    3.3.7 PILOT FLAME ADJUSTMENT For proper operation, the pilot and main burner flames must be steady and not lifting off or floating. The top 3/8” – 1/2” (10-13mm) of the Thermocouple should be engulfed by the pilot flame. 3.3.8 PRIMARY AIR ADJUSTMENT / AJUSTEMENT DE L'AIR PRIMAIRE Aeration is factory set but may need adjustment for altitude or movement during shipping.
  • Page 37: Altitude Adjustment

    3.3.9 ALTITUDE ADJUSTMENT Altitude Natural Gas – Propane Gas – Orifice Size Orifice Size 0 – 2000 ft (0 – 610 m) 2000 – 4000 ft (610 - 1219 m) 4000 – 6000 ft (1219 - 1829 m) All valves have been pre-set and certified for installation at elevations from 0 – 2000 feet (0-610m) above sea level.
  • Page 38 Pilot Box Showing the left Access Panel with burner pan removed 3/. Remove the access panels, one on either side of the pilot box / Retirer les panneaux d'accès, une de chaque côté de la zone pilote 4/. The fan is attached with magnets for ease of installation and can be pulled off the rear wall. / Les fan sont attachés avec des aimants pour la facilité...
  • Page 39: Gas Valve Access

    The pictures above show the electrical box that controls the fan, the power cord attached and the strain relief connected to the box. / Les photos ci-dessus montrent la boîte électrique qui contrôle le ventilateur, le cordon d'alimentation fourni et le réducteur de tension connecté à la boîte. 3.3.11 GAS VALVE ACCESSIBILITY / ACCESSIBILITÉ...
  • Page 40: Maintenance

    4.0 MAINTENANCE 4.1 MAINTENANCE SAFETY / SÉCURITÉ ENTRETIEN WARNING AVERTISSEMENT TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO 30 MINUTES BEFORE SERVICING. COUPEZ LE GAZ AU BRÛLEUR PRINCIPAL ET LAISSEZ L'APPAREIL REFROIDIR PENDANT JUSQU'À...
  • Page 41: Glass Cleaning

    entier et tous les passages d'air. Nettoyer le brûleur. Après tout est propre, vérifier toutes les connexions et la masse du châssis et montons. Nettoyez la vitre. 4.3 GLASS CLEANING / NETTOYAGE DE LA VITRE The inside of the glass may require periodic cleaning to remove deposits left from impurities in the gas and combustion air.
  • Page 42 3. Remove the burner by loosening the screws and lifting it out see section 3.3.9. If the decorative glass is removed from the burner pan make sure you do not get any medium around the pilot when replacing it. / Enlever le brûleur en desserrant les vis et en soulevant it out voir la section 3.3.9.
  • Page 43: Trouble Shooting

    5.0 TROUBLE SHOOTING SYMPTOM CORRECTIVE ACTION POSSIBLE CAUSE Pilot will not light after A. No spark at electrode (weak or not heat source for pilot ignition) repeated triggering of the piezo ignition button 1. Improper ignition 1. Align the electrode with 1/8” (3mm) gap to pilot hood 2.
  • Page 44 A. Valve / Switches III. Main burner will not light 1. Valve control off 1. Turn to “ON” position 2. Blockage at the burner (line, 2. Check and clean orifice, or ports) 3. Defective wall switch 3. Conduct a continuity test or jumper wire thermostat test and replace if defective 4.
  • Page 45 TROUBLE SHOOTING - INTERMITTENT PILOT SYMPTOM CORRECTIVE ACTION POSSIBLE CAUSE A. No spark at electrode (weak or not heat source for pilot ignition) I. Pilot will not light after repeated triggering of the remote control – intermittent pilot 1. Improper ignition 1.
  • Page 46 4. Defective wiring or connections 4. Conduct a test with a jumper wire and repair as required 5. Defective Valve 5. Contact service technician III. Soot deposits 1. Air inlet blocked or restricted Clean air inlets 2. Vent system is restricted or 2.
  • Page 47: Replacement Parts

    6.0 REPLACEMENT PARTS When requesting service or replacement parts for your unit, please provide model name and serial number. All parts listed below may be ordered from an authorized dealer. Description Part# Certification Door Burner Left 708L Burner Right 708R IMC1057A CSA / UL Door Glass...
  • Page 48: Warranty

    After the first year, Sierra Flame may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective parts.
  • Page 49 This warranty defines the obligations and liability of Sierra Flame with respect to the Sierra Flame gas fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
  • Page 50 Après la première année, Sierra Flame, à sa discrétion, se décharger de toutes obligations à l'égard de cette garantie en remboursant à l'acheteur d'origine le prix de gros de toute pièce garantie qui est défectueuse (s).
  • Page 51: Label Information

    8.0 LABEL INFORMATION Page 51 of 58...
  • Page 52 8.0 LABEL INFORMATION (continued) WARNING Electrical Grounding Instructions This appliance is equipped with a three prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or remove the grounding prong from this plug.
  • Page 53 APPENDIX A (AMERICAN FLAME VALVE INFORMATION) Page 53 of 58...
  • Page 54 APPENDIX A (Continued) Page 54 of 58...
  • Page 55 APPENDIX A (Continued) Special Features on the AF-4000 System The AF-4000 Module can be powered two different ways. The first is a standard 110 volt AC to 6.0 volt DC adaptor. This adapter is connected to the AF-4000 Module by connecting the two 1/4” female terminals from the adapter to the two 1/4”...
  • Page 56: Appendix B (Ng - Lp Conversion Kits)

    APPENDIX A (Continued) AF-4000 Wiring Diagram APPENDIX B (NG – LP CONVERSION KITS) This kit will convert the fireplace to Natural Gas / Propane (as applicable). / Ce kit vous permet de convertir la cheminée au gaz naturel / propane (le cas échéant). The Elite models are designed to burn either natural gas or propane.
  • Page 57 WARNING AVERTISSEMENT THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE , EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
  • Page 58 NGCKLCF55 ou LPCKLCF55 aussi clairement marqué sur le bas de la plaque l'étiquette du fabricant par le agence de service qualifié ci-dessus nommé / technicien qui accepte la responsabilité que la conversion a été dûment remplie selon les instructions contenues dans ce manuel. Sierra Flame #1503-7088 18th Ave., Burnaby, BC V3N 0A2...

Table of Contents