ECR International Pennco FSB II Series Installation, Operation & Maintenance Manual page 25

Gas-fired hot water induced draft boiler
Table of Contents

Advertisement

WARNING
!
If you do not follow these instructions
exactly, a fi re or explosion may result
causing property damage, personal injury
or loss of life.
• This appliance is equipped with an ignition device
which automatically lights burner. Do NOT try to
light this burner by hand.
• Before operating smell all around appliance area
for gas. Be sure to smell next to fl oor because
some gas is heavier than air and will settle to the
fl oor.
• Use only your hand to turn the gas shutoff
valve. Never use tools. If valve will not turn by
hand, do not try to repair it, call a qualifi ed ser-
vice technician. Force or attempted repair may
result in fi re or explosion.
• Do not use this appliance if any part has
been under water. Immediately call a quali-
fi ed service technician to inspect appliance and to
replace any part of control system and any gas
control which has been under water.
LIGHTING PROCEDURE FOR BOILER WITH
INTERMITTENT PILOT SYSTEM
For Your Safety, Read Before Operating!!
A. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to light
appliance by hand.
CAUTION
!
!
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switches; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fi re
department.
STARTING YOUR BOILER
Operating Instructions.
STOP! Read Safety Information on previous page.
1.
Set the thermostat to lowest setting.
2.
Turn off all electric power to the appliance.
3.
This appliance is equipped with an ignition device which
4.
automatically lights the burner. Do not attempt to light
pilot by hand.
Remove burner access panel.
5.
Figure 13
INLET
GAS CONTROL KNOB
SHOWN IN "ON" POSITION
Depress gas control knob slightly and turn clockwise
6.
Wait fi ve (5) minutes to clear out any gas. If you then
7.
smell gas STOP! Follow WHAT TO DO IF YOU SMELL
GAS. If you don't smell gas, go to next step.
Turn gas control knob counterclockwise
8.
Turn on all electric power to the appliance.
9.
Set thermostat to desired setting.
10.
After visually inspecting the fl ame, replace lower front
11.
panel.
If appliance will not operate after several tries, turn gas
12.
control knob to "OFF" and call your service technician
or gas supplier.
To Turn Off Gas To The Appliance
Set the thermostat to lowest setting.
1.
Turn off all electric power to the appliance if servicing is
2.
to be performed.
Depress gas control knob slightly and turn clockwise
3.
25
- Gas Control Knob
OFF
to "OFF" position.
to "OFF" position. Do not force.
ON
to "ON."