MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING
CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be followed, including the following:
REQUIRED TOOLS:
• Phillips Screwdriver
• Stiff Bristle Brush
• Adjustable Wrench
• Vacuum Cleaner
Step 1
Disconnect power to unit.
Step 2
Image 3.
Take off rear lower grill assembly by removing (2) side
screws.
Step 3
Remove bolts connecting frame rail cross bar to allow
access to compressor.
Step 4
Remove bolts anchoring compressor assembly to frame
rails and carefully slide out. (tube connections are
flexible)
Step 5
Clean off accumulated dirt from condensing coil with a
Image 4.
stiff bristle brush.
Step 6
Lift W.R. Board cover above fan at plastic plugs and
carefully clean condenser coil and fan blades.
Step 7
After brushing condenser coil vacuum dirt from coil, and
interior floor.
Step 8
Replace cardboard cover. Carefully slide compressor
assembly back into position and replace bolts.
Step 9
Reinstall rear grill assembly onto unit with appropriate
screws. Tighten all screws.
Step 10
Connect unit to power and check to see if compressor is
running.